Literature DB >> 9760902

Measurements of bone and frame-work deformations induced by misfit of implant superstructures. A pilot study in rabbits.

T Jemt1, U Lekholm.   

Abstract

This in vivo study used a 3-D photogrammetric technique to measure distortion of 3 unit implant frame-works and bone surrounding osseointegrated implants after securing misfitting superstructures to the implants. Four adult loop-eared rabbits were provided with 3 implants each in the proximal part of 1 tibia each. After a healing period of 8 weeks, a titanium frame-work was connected with a misfit to the central implant. Three-dimensional photographs were taken before and after securing the central screw, which induced a calculated mean preload of 246 N. Measurements and comparisons of the topography of the frame-works and surrounding bone before and after tightening the central screw indicated a complex and inconsistent deformation pattern. Generally, it could be observed that the top edge of the central cylinder showed vertical movement towards the bone of about 150 microns, always in combination with a rotation of the entire super-structure. The head of the central implant seemed to show a corresponding displacement towards the frame-work of about 50 to 200 microns. Bone deformation was found to be basically localized between the implants, where compressions of about half a millimetre were observed. This concentration of bone deformation as a result of misfit may be one contributing factor to initial marginal bone loss, occasionally observed after insertion of implant supported prostheses.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9760902     DOI: 10.1034/j.1600-0501.1998.090408.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling.

Authors:  Begoña Oteiza-Galdón; Amparo Martínez-González; Ángel-Vicente Escuder
Journal:  J Clin Exp Dent       Date:  2020-10-01

2.  Implant-supported fixed restoration of post-traumatic mandibular defect accompanied with skin grafting: A clinical report.

Authors:  Kwantae Noh; Woo-Jin Choi; Ahran Pae
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

3.  Three-dimensional accuracy of different correction methods for cast implant bars.

Authors:  Ji-Yung Kwon; Chang-Whe Kim; Young-Jun Lim; Ho-Beom Kwon; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

4.  Evaluation of Marginal Misfit of Metal Frameworks Welded by Gas-Torch, Laser, and Tungsten Inert Gas Methods.

Authors:  Wilson Matsumoto; Paula Pastana Beraldo; Rossana Pereira de Almeida; Ana Paula Macedo; Beatriz Roque Kubata; Takami Hirono Hotta
Journal:  Int J Dent       Date:  2018-10-30

5.  Effect of cast rectifiers on the marginal fit of UCLA abutments.

Authors:  Ana Paula Gumieiro Jaime; Diego Klee de Vasconcellos; Alfredo Mikail Melo Mesquita; Estevão Tomomitsu Kimpara; Marco Antonio Bottino
Journal:  J Appl Oral Sci       Date:  2007-06       Impact factor: 2.698

6.  Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones.

Authors:  Ioannis Kioleoglou; Argirios Pissiotis; Michalakis Konstantinos
Journal:  J Clin Exp Dent       Date:  2018-03-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.