Literature DB >> 9758453

Use of an internal fixator device to treat comminuted fractures of the distal radius: report of a technique.

J L Becton1, G L Colborn, J A Goodrich.   

Abstract

An internal fixator technique for stabilizing comminuted Colles fractures has been developed in the anatomy laboratory and used in 35 clinical cases. The Colles Fracture Plate (Biomet, Inc, Warsaw, Indiana) can be used to treat any comminuted Colles fracture for which an external fixator is considered proper management. We have determined, based on our surgical experience with both the internal and external fixator techniques, that internal fixation using the Colles Fracture Plate is technically just as simple as external fixation. In addition to requiring a significantly less expensive device, internal fixation using this technique offers the advantages of better patient acceptance and fewer complications. This report will be followed by a more comprehensive analysis of the technical outcome of this procedure to further substantiate the initial results presented here. The process of compiling and analyzing these data is under way.

Entities:  

Mesh:

Year:  1998        PMID: 9758453

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  9 in total

1.  Anatomic relationships in distal radius bridge plating: a cadaveric study.

Authors:  Jason Dahl; Daniel J Lee; John C Elfar
Journal:  Hand (N Y)       Date:  2015-07-07

2.  Volar long locking compression plate fixation for distal radius fractures with metaphyseal and diaphyseal extension.

Authors:  Sang Ki Lee; Dong Wook Seo; Kap Jung Kim; Dae Suk Yang; Won Sik Choy
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-04-19

Review 3.  Dorsal distraction plating for highly comminuted distal radius fractures.

Authors:  Daniel J Lee; John C Elfar
Journal:  J Hand Surg Am       Date:  2014-11-15       Impact factor: 2.230

4.  "Sandwich" plating for intra-articular distal radius fractures with volar and dorsal metaphyseal comminution.

Authors:  Charles S Day; Atul F Kamath; Eric Makhni; Jerome Jean-Gilles; David Zurakowski
Journal:  Hand (N Y)       Date:  2007-07-13

Review 5.  Review of Internal Radiocarpal Distraction Plating for Distal Radius Fracture Fixation.

Authors:  Venus Vakhshori; Ram Kiran Alluri; Milan Stevanovic; Alidad Ghiassi
Journal:  Hand (N Y)       Date:  2018-07-13

6.  Role of a spanning plate as an internal fixator in complex distal radius fractures.

Authors:  Frank J P Beeres; Rémy Liechti; Björn-Christian Link; Reto Babst
Journal:  Oper Orthop Traumatol       Date:  2020-11-27       Impact factor: 1.154

Review 7.  Dorsal Wrist Spanning Plate Fixation for Treatment of Radiocarpal Fracture-Dislocations.

Authors:  Elizabeth P Wahl; Alexander S Lauder; Tyler S Pidgeon; Evan M Guerrero; David S Ruch; Marc J Richard
Journal:  Hand (N Y)       Date:  2019-12-17

8.  Can Radiocarpal-Spanning Fixation Be Made More Functional by Placing the Wrist in Extension? A Biomechanical Study Under Physiologic Loads.

Authors:  Tobias Mann; Daniel J Lee; Jason Dahl; John C Elfar
Journal:  Geriatr Orthop Surg Rehabil       Date:  2016-03

9.  Radiographic Outcomes of Dorsal Spanning Plate for Treatment of Comminuted Distal Radius Fractures in Non-Elderly Patients.

Authors:  Behnam Sharareh; Scott Mitchell
Journal:  J Hand Surg Glob Online       Date:  2019-11-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.