Literature DB >> 9758381

Transthoracic echocardiographic measurement of coronary artery diameter: validation against quantitative coronary angiography.

D J Hildick-Smith1, L M Shapiro.   

Abstract

There has been no in vivo validation of the use of transthoracic echocardiography to measure distal left anterior descending coronary artery (LAD) diameter. We therefore undertook transthoracic echocardiography on 65 male patients immediately before cardiac catheterization to compare echocardiographic and angiographic findings. The distal LAD was successfully imaged in 41 (63%) patients; 29 of these had an angiographically normal distal LAD as assessed by an independent cardiologist and formed the study group. Transthoracic echocardiographic and quantitative coronary angiographic measurements of distal LAD diameter were made. Echocardiographic measurements ranged from 0.14 to 0.28 cm (mean 0.20 cm). Angiographic results ranged from 0.12 to 0.28 cm (mean 0.195 cm). Correlation between techniques was good (r=.925). The maximum discrepancy between transthoracic echocardiography and quantitative coronary angiography was 0.03 cm. Limits of agreement were +0.032 to -0.024 cm. We conclude that transthoracic echocardiography is a valid technique for measurement of distal LAD diameter.

Entities:  

Mesh:

Year:  1998        PMID: 9758381     DOI: 10.1016/s0894-7317(98)70009-4

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

1.  Coronary flow reserve is supranormal in endurance athletes: an adenosine transthoracic echocardiographic study.

Authors:  D J Hildick-Smith; P J Johnson; C R Wisbey; E M Winter; L M Shapiro
Journal:  Heart       Date:  2000-10       Impact factor: 5.994

2.  Coronary Diameters in Taiwanese Children Younger than 6 Years Old: Z-Score Regression Equations Derived from Body Surface Area.

Authors:  Ming-Tai Lin; Chin-Hao Chang; Wen-Chin Hsieh; Chi-En Chang; Ya-Mei Chang; Yung-Chuan Chen; Jui-Yu Hsu; Yi-Ling Huang; Juine-Yih Ma; Li-Chuan Sun; Chi-Sen Wu; Su-Zen Yeh; Wei-Quan Fang; Chun-An Chen; Shuenn-Nan Chiu; Chun-Wei Lu; Jou-Kou Wang; Mei-Hwan Wu
Journal:  Acta Cardiol Sin       Date:  2014-07       Impact factor: 2.672

3.  eG Coated Stents Exhibit Enhanced Endothelial Wound Healing Characteristics.

Authors:  Belen Rodriguez-Garcia; Christophe Bureau; Abdul I Barakat
Journal:  Cardiovasc Eng Technol       Date:  2021-05-18       Impact factor: 2.495

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.