[Thyroglobulin assay ambiguities].

R Sapin1, J L Schlienger.   

Abstract

Thyroglobulin immunometric "sandwich" assays (IMA) have taken over competitive radioimmunoassays, but this assay remains problematic. A human thyroglobulin reference material (CRM 457) has been prepared but is not widely used. That constitutes the main cause of very marked between kit variability of thyroglobulin results. High-dose hook effect, which can falsely decrease the result of a serum with high concentration of thyroglobulin, is not exceptional in one-step assays and should be systematically checked. Selection of monoclonal antibodies with no cross-reactivity with anti-thyroglobulin autoantibodies or of polyclonal antibodies with very high affinity, have reduced the frequency of interference due to autoantibodies, but did not abolish it. Recovery test is used to detect such interference, but with insufficient sensitivity. In fact, recovery determination can be influenced by the nature of thyroglobulin added to the serum (not identical to endogenous thyroglobulin), by the delay of incubation of exogenous thyroglobulin and serum autoantibodies and by the amount of added thyroglobulin. In addition, recovery is often wrongly expressed as the observed/theoretic ratio of final concentrations instead of added concentrations. In untreated Graves' disease patients and despite normal recovery test, thyroglobulin measured by IMA is lower when anti-thyroglobulin autoantibodies are present. Consequently, thyroglobulin result should be interpreted in function of presence or absence of autoantibodies. Development of total (free and autoantibody bound) thyroglobulin assay would be useful to evaluate assay and recovery test performances.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9754221

Source DB:  PubMed          Journal:  Ann Biol Clin (Paris)        ISSN: 0003-3898            Impact factor:   0.459


  2 in total

1.  In vitro assays to test the interference of anti-thyroglobulin antibodies on thyroglobulin measurement.

Authors:  Deolinda Madureira; Susana Prazeres; Márcia São Pedro; Teresa Pereira; Ana Paula Font; Maria João Bugalho
Journal:  Endocrine       Date:  2008-03-29       Impact factor: 3.633

2.  Giant invasive pituitary prolactinoma with falsely low serum prolactin: the significance of 'hook effect'.

Authors:  Maria Fleseriu; Michael Lee; Maria M Pineyro; Mario Skugor; Sethu K Reddy; Elias S Siraj; Amir H Hamrahian
Journal:  J Neurooncol       Date:  2006-04-06       Impact factor: 4.130

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.