Accuracy of single-dipole inverse solution when localising ventricular pre-excitation sites: simulation study.

R Hren1, G Stroink, B M Horácek.   

Abstract

Different factors are investigated that may affect the accuracy of an inverse solution that uses a single-dipole equivalent generator, in a standardised inhomogeneous torso model, when localising the pre-excitation sites. An anatomical model of the human ventricular myocardium is used to simulate body surface potential maps (BSPMs) and magnetic field maps (MFMs) for 35 pre-excitation sites positioned on the epicardial surface along the atrioventricular ring. The sites of pre-excitation activity are estimated by the single-dipole method, and the measure for the accuracy of the localisation is the localisation error, defined as the distance between the location of the best-fitting single dipole and the actual site of pre-excitation in the ventricular model. The findings indicate that, when the electrical properties of the volume conductor and lead positions are precisely known and the 'measurement' noise is added to the simulated BSPMs and MFMs, the single-dipole method optimally localises the pre-excitation activity 20 ms after the onset of pre-excitation, within 0.71 +/- 0.28 cm and 0.65 +/- 0.30 cm using BSPMs and MFMs, respectively. When the standard torso model is used to localise the sites of onset of the pre-excitation sequence initiated in four individualised torso models, the maximum errors are as high as 2.6-3.0 cm (even though the average error, for both the BSPM and MFM localisations, remains within the 1.0-1.5 cm range). In spite of these shortcomings, it is thought that single-dipole localisations can be useful for non-invasive pre-interventional planning.

Entities:  

Mesh:

Year:  1998        PMID: 9747572     DOI: 10.1007/bf02522478

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  26 in total

1.  A computer model for the study of electrical current flow in the human thorax.

Authors:  C R Johnson; R S MacLeod; P R Ershler
Journal:  Comput Biol Med       Date:  1992-09       Impact factor: 4.589

2.  Clinical magnetocardiography. 10 years experience at the Catholic University.

Authors:  R R Fenici; G Melillo; M Masselli
Journal:  Int J Card Imaging       Date:  1991

3.  Body surface mapping of ectopic left and right ventricular activation. QRS spectrum in patients without structural heart disease.

Authors:  A SippensGroenewegen; H Spekhorst; N M van Hemel; J H Kingma; R N Hauer; M J Janse; A J Dunning
Journal:  Circulation       Date:  1990-09       Impact factor: 29.690

4.  Comparison between electrocardiographic and magnetocardiographic inverse solutions using the boundary element method.

Authors:  R Hren; X Zhang; G Stroink
Journal:  Med Biol Eng Comput       Date:  1996-03       Impact factor: 2.602

5.  Biomagnetic noninvasive localization of accessory pathways in Wolff-Parkinson-White syndrome.

Authors:  P Weismüller; K Abraham-Fuchs; S Schneider; P Richter; M Kochs; J Edrich; V Hombach
Journal:  Pacing Clin Electrophysiol       Date:  1991-11       Impact factor: 1.976

6.  Value of simulated body surface potential maps as templates in localizing sites of ectopic activation for radiofrequency ablation.

Authors:  R Hren; B M Horácek
Journal:  Physiol Meas       Date:  1997-11       Impact factor: 2.833

7.  The effect of torso inhomogeneities on body surface potentials quantified using "tailored" geometry.

Authors:  A van Oosterom; G J Huiskamp
Journal:  J Electrocardiol       Date:  1989-01       Impact factor: 1.438

8.  Curative percutaneous catheter ablation using radiofrequency energy for accessory pathways in all locations: results in 100 consecutive patients.

Authors:  M D Lesh; G F Van Hare; D J Schamp; W Chien; M A Lee; J C Griffin; J J Langberg; T J Cohen; K G Lurie; M M Scheinman
Journal:  J Am Coll Cardiol       Date:  1992-05       Impact factor: 24.094

9.  Evaluation of the non-invasive localization accuracy of cardiac arrhythmias attainable by multichannel magnetocardiography (MCG).

Authors:  W Moshage; S Achenbach; K Göhl; K Bachmann
Journal:  Int J Card Imaging       Date:  1996-03

10.  Body surface mapping of ectopic left ventricular activation. QRS spectrum in patients with prior myocardial infarction.

Authors:  A SippensGroenewegen; H Spekhorst; N M van Hemel; J H Kingma; R N Hauer; M J Janse; A J Dunning
Journal:  Circ Res       Date:  1992-12       Impact factor: 17.367

View more
  5 in total

1.  Multichannel magnetocardiographic measurements with a physical thorax phantom.

Authors:  K Pesola; U Tenner; J Nenonen; P Endt; H Brauer; U Leder; T Katila
Journal:  Med Biol Eng Comput       Date:  1999-01       Impact factor: 2.602

2.  Visualization of three-dimensional cardiac electrical excitation using standard heart model and anterior and posterior magnetocardiogram.

Authors:  Kuniomi Ogata; Akihiko Kandori; Tsuyoshi Miyashita; Keiji Tsukada; Satoshi Nakatani; Wataru Shimizu; Hideaki Kanzaki; Kunio Miyatake; Satsuki Yamada; Shigeyuki Watanabe; Iwao Yamaguchi
Journal:  Int J Cardiovasc Imaging       Date:  2006-03-07       Impact factor: 2.357

3.  Equivalent moving dipole localization of cardiac ectopic activity in a swine model during pacing.

Authors:  Dakun Lai; Chenguang Liu; Michael D Eggen; Paul A Iaizzo; Bin He
Journal:  IEEE Trans Inf Technol Biomed       Date:  2010-05-27

4.  Classifying cases of fetal Wolff-Parkinson-White syndrome by estimating the accessory pathway from fetal magnetocardiograms.

Authors:  A Kandori; T Hosono; Y Chiba; M Shinto; S Miyashita; M Murakami; T Miyashita; K Ogata; K Tsukada
Journal:  Med Biol Eng Comput       Date:  2003-01       Impact factor: 2.602

5.  Value and limitations of an inverse solution for two equivalent dipoles in localising dual accessory pathways.

Authors:  V Jazbinsek; R Hren; G Stroink; B M Horácek; Z Trontelj
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.