Comparison between electrocardiographic and magnetocardiographic inverse solutions using the boundary element method.

R Hren1, X Zhang, G Stroink.   

Abstract

The accuracy of imaging cardiac sources using electrocardiographic and magnetocardiographic signals is influenced by thoracic inhomogeneities, e.g. the lungs and cardiac blood masses. The effects is investigated of such inhomogeneities on the body-surface potential maps (BSPM) and magnetic-field maps (MFM) inverse solutions for a single moving dipole as the source model and a realistic torso model as the volume conductor, by employing a node-based boundary element method. Using the same number and placement of the body-surface potential and magnetic field leads, a comparison is obtained of the numerical accuracy of body-surface potential and magnetic field leads. The results show that, with no noise added, the body-surface potential solution is less sensitive to the exclusion of the inhomogeneities than the magnetic field solution. The influence of noise on the BSPM and MFM localization is comparable for x (left-right) and y (foot-head) oriented dipoles, and the BSPM localisation is more accurate than the MFM localisation for z (anterior-posterior) oriented dipoles.

Entities:  

Mesh:

Year:  1996        PMID: 8733546     DOI: 10.1007/bf02520014

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  A linear discretization of the volume conductor boundary integral equation using analytically integrated elements.

Authors:  J C de Munck
Journal:  IEEE Trans Biomed Eng       Date:  1992-09       Impact factor: 4.538

Review 2.  The preexcitation syndromes.

Authors:  J J Gallagher; E L Pritchett; W C Sealy; J Kasell; A G Wallace
Journal:  Prog Cardiovasc Dis       Date:  1978 Jan-Feb       Impact factor: 8.194

3.  Moving dipole inverse solutions using realistic torso models.

Authors:  C J Purcell; G Stroink
Journal:  IEEE Trans Biomed Eng       Date:  1991-01       Impact factor: 4.538

4.  Magnetocardiographic functional localization using a current dipole in a realistic torso.

Authors:  J Nenonen; C J Purcell; B M Horacek; G Stroink; T Katila
Journal:  IEEE Trans Biomed Eng       Date:  1991-07       Impact factor: 4.538

5.  Magnetocardiographic functional localization using current multipole models.

Authors:  J Nenonen; T Katila; M Leiniö; J Montonen; M Mäkijärvi; P Siltanen
Journal:  IEEE Trans Biomed Eng       Date:  1991-07       Impact factor: 4.538

Review 6.  The inverse problem in electrocardiography: solutions in terms of equivalent sources.

Authors:  R M Gulrajani; P Savard; F A Roberge
Journal:  Crit Rev Biomed Eng       Date:  1988

7.  Effect of torso boundaries on electric potential and magnetic field of a dipole.

Authors:  C J Purcell; G Stroink; B M Horacek
Journal:  IEEE Trans Biomed Eng       Date:  1988-09       Impact factor: 4.538

8.  Source parameter estimation in inhomogeneous volume conductors of arbitrary shape.

Authors:  T F Oostendorp; A van Oosterom
Journal:  IEEE Trans Biomed Eng       Date:  1989-03       Impact factor: 4.538

9.  A complete linear discretization for calculating the magnetic field using the boundary element method.

Authors:  A S Ferguson; X Zhang; G Stroink
Journal:  IEEE Trans Biomed Eng       Date:  1994-05       Impact factor: 4.538

10.  The influence of inhomogeneous volume conductor models on the ECG and the MCG.

Authors:  H Bruder; B Scholz; K Abraham-Fuchs
Journal:  Phys Med Biol       Date:  1994-11       Impact factor: 3.609

View more
  6 in total

1.  Multichannel magnetocardiographic measurements with a physical thorax phantom.

Authors:  K Pesola; U Tenner; J Nenonen; P Endt; H Brauer; U Leder; T Katila
Journal:  Med Biol Eng Comput       Date:  1999-01       Impact factor: 2.602

2.  Methods for the computational localization of atrio-ventricular pre-excitation syndromes.

Authors:  U Leder; J Haueisen; P Pohl; F M Malur; J P Heyne; V Baier; H R Figulla
Journal:  Int J Cardiovasc Imaging       Date:  2001-04       Impact factor: 2.357

3.  Classifying cases of fetal Wolff-Parkinson-White syndrome by estimating the accessory pathway from fetal magnetocardiograms.

Authors:  A Kandori; T Hosono; Y Chiba; M Shinto; S Miyashita; M Murakami; T Miyashita; K Ogata; K Tsukada
Journal:  Med Biol Eng Comput       Date:  2003-01       Impact factor: 2.602

4.  Spatial resolution of body surface potential maps and magnetic field maps: a simulation study applied to the identification of ventricular pre-excitation sites.

Authors:  R Hren; G Stroink; B M Horácek
Journal:  Med Biol Eng Comput       Date:  1998-03       Impact factor: 2.602

5.  Accuracy of single-dipole inverse solution when localising ventricular pre-excitation sites: simulation study.

Authors:  R Hren; G Stroink; B M Horácek
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

6.  Optimal Magnetic Sensor Vests for Cardiac Source Imaging.

Authors:  Stephan Lau; Bojana Petković; Jens Haueisen
Journal:  Sensors (Basel)       Date:  2016-05-24       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.