Fifteen years experience with finger arterial pressure monitoring: assessment of the technology.

B P Imholz1, W Wieling, G A van Montfrans, K H Wesseling.   

Abstract

We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in comparison with intra-arterial or with noninvasive but intermittent blood pressure measurements. We compiled the results of 43 such papers and found systolic, diastolic and mean accuracies, in this order, ranging from -48 to 30 mmHg, from -20 to 18 mmHg, and from -13 to 25 mmHg. Weighted for the number of subjects included pooled accuracies were -0.8 (SD 11.9), -1.6 (8.3) and -1.6 (7.6) mmHg respectively. Subdividing the pooled group according to criteria such as reference blood pressure, place of application, and prototype or commercial device we found no significant differences in mean differences or SD. Measurement at the finger allows uninterrupted recordings of long duration. The transmission of the pressure pulse along the arm arteries, however, causes distortion of the pulse waveform and depression of the mean blood pressure level. These effects can be reduced by appropriate filtering, and upper arm 'return-to-flow' calibration to bring accuracy and precision within AAMI limits. For the assessment of beat-to-beat changes in blood pressure and assessment of blood pressure variability Finapres proved a reliable alternative for invasive measurements when mean and diastolic pressures are concerned. Differences in systolic pressure are larger and reach statistical significance but are not of clinical relevance. Finger arteries are affected by contraction and dilatation in relation to psychological and physical (heat, cold, blood loss, orthostasis) stress. Effects of these phenomena are reduced by the built-in Physiocal algorithm. However, full smooth muscle contraction should be avoided in the awake patient by comforting the patient, and covering the hand. Arterial state can be monitored by observing the behaviour of the Physiocal algorithm. We conclude that Finapres accuracy and precision usually suffice for reliable tracking of changes in blood pressure. Diagnostic accuracy may be achieved with future application of corrective measures.

Entities:  

Mesh:

Year:  1998        PMID: 9747429     DOI: 10.1016/s0008-6363(98)00067-4

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  142 in total

1.  Treatment of vasovagal syncope: pacemaker or crossing legs?

Authors:  N van Dijk; M P Harms; M Linzer; W Wieling
Journal:  Clin Auton Res       Date:  2000-12       Impact factor: 4.435

2.  Influence of microgravity on astronauts' sympathetic and vagal responses to Valsalva's manoeuvre.

Authors:  James F Cox; Kari U O Tahvanainen; Tom A Kuusela; Benjamin D Levine; William H Cooke; Tadaaki Mano; Satoshi Iwase; Mitsuru Saito; Yoshiki Sugiyama; Andrew C Ertl; Italo Biaggioni; André Diedrich; Rose Marie Robertson; Julie H Zuckerman; Lynda D Lane; Chester A Ray; Ronald J White; James A Pawelczyk; Jay C Buckey; Friedhelm J Baisch; C Gunnar Blomqvist; David Robertson; Dwain L Eckberg
Journal:  J Physiol       Date:  2002-01-01       Impact factor: 5.182

3.  Postextrasystolic regulation patterns of blood pressure and heart rate in patients with idiopathic dilated cardiomyopathy.

Authors:  Andreas Voss; Vico Baier; Agnes Schumann; Annette Hasart; Franziska Reinsperger; Alexander Schirdewan; Karl-Josef Osterziel; Uwe Leder
Journal:  J Physiol       Date:  2002-01-01       Impact factor: 5.182

4.  Continuous mean arterial pressure measurement in the fingers: the influence of local arm cooling.

Authors:  R Raamat; K Jagomägi; J Talts; E Länsimies; J Jurvelin; P Kolari
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

Review 5.  The riddles of heart rate variability.

Authors:  J M Karemaker
Journal:  Clin Auton Res       Date:  2001-04       Impact factor: 4.435

6.  Joint symbolic dynamic analysis of beat-to-beat interactions of heart rate and systolic blood pressure in normal pregnancy.

Authors:  M Baumert; T Walther; J Hopfe; H Stepan; R Faber; A Voss
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

7.  Assessment of short-term blood pressure variability in anesthetized children: a comparative study between intraarterial and finger blood pressure.

Authors:  I Constant; D Laude; J L Elghozi; I Murat
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

8.  A comparative assessment of two techniques for investigating initial cardiovascular reflexes under acute orthostatic stress.

Authors:  Caroline A Rickards; David G Newman
Journal:  Eur J Appl Physiol       Date:  2003-07-19       Impact factor: 3.078

9.  Finger photoplethysmography during the Valsalva maneuver reflects left ventricular filling pressure.

Authors:  Harry A Silber; Jeffrey C Trost; Peter V Johnston; W Lowell Maughan; Nae-Yuh Wang; Edward K Kasper; Thomas R Aversano; David E Bush
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-03-02       Impact factor: 4.733

Review 10.  Nonpharmacological treatment of reflex syncope.

Authors:  Wouter Wieling; Nancy Colman; C T Paul Krediet; Roy Freeman
Journal:  Clin Auton Res       Date:  2004-10       Impact factor: 4.435