Literature DB >> 22389389

Finger photoplethysmography during the Valsalva maneuver reflects left ventricular filling pressure.

Harry A Silber1, Jeffrey C Trost, Peter V Johnston, W Lowell Maughan, Nae-Yuh Wang, Edward K Kasper, Thomas R Aversano, David E Bush.   

Abstract

It is often challenging to assess cardiac filling pressure clinically. An improved system for detecting or ruling out elevated cardiac filling pressure may help reduce hospitalizations for heart failure. The blood pressure response to the Valsalva maneuver reflects left heart filling pressure, but its underuse clinically may be due in part to lack of continuous blood pressure recording along with lack of standardization of expiratory effort. In this study, we tested whether Valsalva-induced changes in the pulse amplitude of finger photoplethysmography (PPG), a technology already widely available in medical settings, correlate with invasively measured left ventricular end-diastolic pressure (LVEDP). We tested 33 subjects before clinically scheduled cardiac catheterizations. A finger photoplethysmography waveform was recorded during a Valsalva effort of 20 mmHg expiratory pressure sustained for 10 s, an effort most patients can achieve. Pulse amplitude ratio (PAR) was calculated as the PPG waveform amplitude just before release of expiratory effort divided by the waveform amplitude at baseline. PAR was well correlated with LVEDP (r = 0.68; P < 0.0001). For identifying LVEDP > 15 mmHG, PAR > 0.4 was 85% sensitive [95% confidence interval (95CI): 54-97%] and 80% specific (95CI: 56-93%). In conclusion, finger PPG, a technology already ubiquitous in medical centers, may be useful for assessing clinically meaningful categories of left heart filling pressure, using simple analysis of the waveform after a Valsalva maneuver effort that most patients can achieve.

Entities:  

Mesh:

Year:  2012        PMID: 22389389      PMCID: PMC3774124          DOI: 10.1152/ajpheart.00609.2011

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  38 in total

1.  A new method of predicting pulmonary capillary wedge pressure: the arterial pressure ratio.

Authors:  H Uehara; I Takenaka; K Aoyama; T Kadoya; T Sata; A Shigematsu
Journal:  Anaesthesia       Date:  2000-02       Impact factor: 6.955

2.  A noninvasive method of predicting pulmonary-capillary wedge pressure.

Authors:  K M McIntyre; J A Vita; C T Lambrew; J Freeman; J Loscalzo
Journal:  N Engl J Med       Date:  1992-12-10       Impact factor: 91.245

3.  Blood pressure responses to the Valsalva maneuver in cardiac patients with and without congestive failure.

Authors:  W E JUDSON; J D HATCHER; R W WILKINS
Journal:  Circulation       Date:  1955-06       Impact factor: 29.690

4.  Detection of elevated pulmonary capillary wedge pressure in elderly patients with various cardiac disorders by the Valsalva manoeuvre.

Authors:  Jaap J Remmen; Wim R M Aengevaeren; Freek W A Verheugt; René W M M Jansen
Journal:  Clin Sci (Lond)       Date:  2006-08       Impact factor: 6.124

5.  Noninvasive monitoring of left ventricular end-diastolic pressure reduces rehospitalization rates in patients hospitalized for heart failure: a randomized controlled trial.

Authors:  G V R K Sharma; Patricia A Woods; Nancy Lindsey; Carol O'Connell; Louise Connolly; Jacob Joseph; Kevin M McIntyre
Journal:  J Card Fail       Date:  2011-09       Impact factor: 5.712

6.  The limited reliability of physical signs for estimating hemodynamics in chronic heart failure.

Authors:  L W Stevenson; J K Perloff
Journal:  JAMA       Date:  1989-02-10       Impact factor: 56.272

7.  The application of photoplethysmography to the recording of Valsalva maneuver responses.

Authors:  J Weinman; S Ben-Yaakov; D Sapoznikov
Journal:  Isr J Med Sci       Date:  1969 Jul-Aug

8.  Accurate detection of elevated left ventricular filling pressure by a simplified bedside application of the Valsalva maneuver.

Authors:  D E Schmidt; P K Shah
Journal:  Am J Cardiol       Date:  1993-02-15       Impact factor: 2.778

9.  Pulse pressure response to the strain of the valsalva maneuver in humans with preserved systolic function.

Authors:  J L Hébert; C Coirault; K Zamani; G Fontaine; Y Lecarpentier; D Chemla
Journal:  J Appl Physiol (1985)       Date:  1998-09

10.  Left ventricular dysfunction--bedside Valsalva manoeuvre.

Authors:  M J Zema; B Restivo; T Sos; K W Sniderman; S Kline
Journal:  Br Heart J       Date:  1980-11
View more
  3 in total

1.  A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis.

Authors:  Panagis Galiatsatos; Kapil Parakh; Jennifer Monti; Sumeska Thavarajah; Harriet Aneke-Ogbu; Amaris Watson; Daniel Kim; Nae-Yuh Wang; Tariq Shafi; Harry A Silber
Journal:  BMC Nephrol       Date:  2015-08-14       Impact factor: 2.388

2.  Effect of sympathetic autonomic stress from the cold pressor test on left ventricular function in young healthy adults.

Authors:  Simiat O Elias; Reina E Ajayi
Journal:  Physiol Rep       Date:  2019-01

3.  Simultaneous beat-by-beat investigation of the effects of the Valsalva maneuver on left and right ventricular filling and the possible mechanism.

Authors:  Zhen Wang; Li-jun Yuan; Tie-sheng Cao; Yong Yang; Yun-you Duan; Chang-yang Xing
Journal:  PLoS One       Date:  2013-01-14       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.