Literature DB >> 9743667

Retrievable cemented implant restorations.

W W Chee1, A Torbati, J P Albouy.   

Abstract

Prostheses can be attached to implants or implant abutments by screw retention, cementation, or with the use of set-screws. The indications for non-screw-retained restorations are discussed with respect to implant body position and surgical limitations for implant placement. The advantages and disadvantages of each method are outlined. A technique that uses a screw threaded into the implant restoration to displace the cemented restoration is presented. Use of this technique will allow predictable removal of the cemented restorations without damage to the prosthesis or abutment.

Mesh:

Substances:

Year:  1998        PMID: 9743667     DOI: 10.1111/j.1532-849x.1998.tb00191.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  Clinical performance of screw-retained and cemented implant-supported zirconia single crowns: 36-month results.

Authors:  Claudio Cacaci; Friederike Cantner; Thomas Mücke; Peter Randelzhofer; Jan Hajtó; Florian Beuer
Journal:  Clin Oral Investig       Date:  2016-10-29       Impact factor: 3.573

2.  Retentiveness of implant-supported metal copings using different luting agents.

Authors:  Farahnaz Nejatidanesh; Omid Savabi; Maziar Ebrahimi; Ghazal Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-01

3.  Modified Glass Ionomer Cement with "Remove on Demand" Properties: An In Vitro Study.

Authors:  Shaza Bishti; Taskin Tuna; Garima Agrawal; Andrij Pich; Stefan Wolfart
Journal:  Dent J (Basel)       Date:  2017-01-23

4.  Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments.

Authors:  Sina Safari; Fereshteh Hosseini Ghavam; Parviz Amini; Kaveh Yaghmaei
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

Review 5.  Retention failures in cement- and screw-retained fixed restorations on dental implants in partially edentulous arches: A systematic review with meta-analysis.

Authors:  Jatin K Jain; Rajesh Sethuraman; Sameer Chauhan; Piyush Javiya; Shreya Srivastava; Rutvik Patel; Bhagyashri Bhalani
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

6.  Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study.

Authors:  Hadi Mokhtarpour; Reza Eftekhar Ashtiani; Minoo Mahshid; Farhad Tabatabaian; Marzieh Alikhasi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-08-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.