Literature DB >> 9743128

Effect of an acidic primer on shear bond strength of orthodontic brackets.

S E Bishara1, V V Gordan, L VonWald, M E Olson.   

Abstract

A unique characteristic of some new etching systems is that they combine the conditioning and priming agents into a single acidic primer solution. The purpose of this study was to determine the effects on the shear bond strength and the bracket/adhesive failure mode when an acidic primer and other enamel etchants were used to condition the enamel surface before bonding. The brackets were bonded to extracted human teeth according to one of four protocols following the manufacturers instructions. Group I, teeth were etched with 37% phosphoric acid, the brackets were then bonded with System 1+ adhesive (Ormco Corporation. Orange, Calif.); group II, teeth were etched with 10% maleic acid, the brackets were also bonded with System 1+ adhesive; group III, an acidic primer that contains both the acid (phenyl-P) and the primer (hema and dimethacrylate) were placed on the enamel for 30 seconds. The adhesive used on this group was a lightly filled resin that contains Bis-GMA and HEMA. (Clearfil Liner Bond 2. J.C. Moritta, Kuraway, Japan); Group IV, the same acidic primer was used as in group II, the adhesive used was highly filled (Panavia 21. J.C. Moritta) and contains Bis-GMA. The present in vitro findings indicated that the use of acidic primers to bond orthodontic brackets to the enamel surface could provide clinically acceptable shear bond forces (x = 10.4 +/- 4.4 MPa) when used with a highly (77%) filled adhesive (Panavia 21). These debonding forces were comparable to those obtained when the enamel was conditioned with either Phosphoric (x = 11.8 +/- 4.1 MPa) or Maleic (x = 10.9 +/- 4.4 MPa) acids. With the use of a lightly (10%) filled adhesive (Clearfil Liner Bond 2), the shear bond strength was significantly lower (x = 5.9 +/- 5.6 MPa). It is of interest to note that there was a tendency to have less residual adhesive remaining on the tooth when an acid primer was used than when phosphoric and maleic acids were used. This might be of advantage to the clinician because it will require less time to clean the teeth after debonding.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9743128     DOI: 10.1016/s0889-5406(98)70205-7

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  23 in total

1.  Effect of saliva contamination on shear bond strength of orthodontic brackets when using a self-etch primer.

Authors:  Jing Mao; Juan Qi
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2005

2.  Shear bond strength of acidic primer, light-cure glass ionomer, light-cure and self cure composite adhesive systems - an in vitro study.

Authors:  Krishnakanth Reddy D; Kishore M S V; Safeena Safeena
Journal:  J Int Oral Health       Date:  2013-06-23

3.  An Ex-vivo Shear and tensile bond strengths of orthodontic molar tubes bonded using different techniques.

Authors:  Elham Abu-Alhaija; Mohammad Jaradat; Ahed Alwahadni
Journal:  J Clin Exp Dent       Date:  2017-03-01

4.  Comparative Evaluation of Microtensile Bond Strength of Three Adhesive Systems.

Authors:  Shiva Jafarnia; Javad Zeinaddini Meymand; Fateme Zandkarimi; Sogol Saberi; Sima Shahabi; Alireza Valanezhad; Sirus Safaee; Mahdis Nesabi; Ikuya Watanabe
Journal:  Front Dent       Date:  2022-02-06

5.  Evaluation of mineral content of enamel prepared by erbium, chromium:yttrium-scandium-gallium-garnet laser.

Authors:  Asli Secilmis; Aslihan Usumez; Serdar Usumez; Gizem Berk
Journal:  Lasers Med Sci       Date:  2009-03-11       Impact factor: 3.161

Review 6.  Enamel etching for bonding fixed orthodontic braces.

Authors:  Haikun Hu; Chunjie Li; Fan Li; Jianwei Chen; Jianfeng Sun; Shujuan Zou; Andrew Sandham; Qiang Xu; Philip Riley; Qingsong Ye
Journal:  Cochrane Database Syst Rev       Date:  2013-11-25

7.  Influence of enamel sandblasting prior to etching on shear bond strength of indirectly bonded lingual appliances.

Authors:  Julio P Cal-Neto; Simone Castro; Pollyana Marques Moura; Daniel Ribeiro; José Augusto M Miguel
Journal:  Angle Orthod       Date:  2011-01       Impact factor: 2.079

8.  A comparison of shear bond strength of orthodontic brackets bonded with four different orthodontic adhesives.

Authors:  Sudhir Sharma; Pradeep Tandon; Amit Nagar; Gyan P Singh; Alka Singh; Vinay K Chugh
Journal:  J Orthod Sci       Date:  2014-04

9.  In vitro evaluation of an alternative method to bond molar tubes.

Authors:  Célia Regina Maio Pinzan-Vercelino; Arnaldo Pinzan; Júlio de Araújo Gurgel; Fausto Silva Bramante; Luciana Maio Pinzan
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

10.  Comparison of Shear Bond Strength of Three Self-etching Adhesives: An In-Vitro Study.

Authors:  Chandrashekhar Yadala; Rajkumar Gaddam; Siddarth Arya; K V Baburamreddy; V Ramakrishnam Raju; Praveen Kumar Varma
Journal:  J Int Oral Health       Date:  2015-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.