Literature DB >> 9740015

In vivo investigation of blood compatibility of titanium oxide films.

F Zhang1, Z Zheng, Y Chen, X Liu, A Chen, Z Jiang.   

Abstract

Titanium oxide films were synthesized by ionbeam-enhanced deposition. The films were prepared by depositing titanium atoms and simultaneously bombarding them with Xe+ ions at an energy of 40 keV in an O2 environment. An in vivo investigation, which entailed implanting low-temperature isotropic pyrolytic carbon (LTI carbon) cylinders, widely used to fabricate artificial heart valves, and titanium-oxide-coated LTI carbon cylinders with diameters of 5 mm and thicknesses of 0.5 mm into the ventral aorta of dogs for 14 days, showed that the amount of thrombus on the titanium-oxide-coated LTI carbon was much less than that formed on the surface of LTI carbon alone. Scanning electron microscopy (SEM) was used to observe the morphology of thrombus. On the titanium oxide films no platelet aggregation was found, almost no red blood cells were damaged, and almost no fibrin was found on the surface. However, all three characteristics were found on the surface of LTI carbon alone, proving that the blood compatibility of titanium oxide films is better than that of LTI carbon and titanium-oxide-coated LTI carbon.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9740015     DOI: 10.1002/(sici)1097-4636(199810)42:1<128::aid-jbm16>3.0.co;2-h

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  7 in total

Review 1.  Wireless and inductively powered implant for measuring electrocardiogram.

Authors:  Jarno Riistama; Juho Väisänen; Sami Heinisuo; Hanna Harjunpää; Satu Arra; Kati Kokko; Maunu Mäntylä; Jutta Kaihilahti; Pekka Heino; Minna Kellomäki; Outi Vainio; Jukka Vanhala; Jukka Lekkala; Jari Hyttinen
Journal:  Med Biol Eng Comput       Date:  2007-10-11       Impact factor: 2.602

2.  Analysis of the cytotoxicity of differentially sized titanium dioxide nanoparticles in murine MC3T3-E1 preosteoblasts.

Authors:  Yilin Zhang; Weiqiang Yu; Xinquan Jiang; Kaige Lv; Shengjun Sun; Fuqiang Zhang
Journal:  J Mater Sci Mater Med       Date:  2011-06-18       Impact factor: 3.896

3.  Graphene coatings for biomedical implants.

Authors:  Ramakrishna Podila; Thomas Moore; Frank Alexis; Apparao Rao
Journal:  J Vis Exp       Date:  2013-03-01       Impact factor: 1.355

4.  Blood compatibility improvement of titanium oxide film modified by doping La(2)O(3).

Authors:  Lin Zhang; Dihu Chen; Keqiang Wang; Fengmei Yu; Zhanyun Huang; Shirong Pan
Journal:  J Mater Sci Mater Med       Date:  2009-05-24       Impact factor: 3.896

5.  Short term evaluation of material blood compatibility using a microchannel array.

Authors:  Kimi Kurotobi; Akiko Yamamoto; Akemi Kikuta; Takao Hanawa
Journal:  J Mater Sci Mater Med       Date:  2007-02-03       Impact factor: 4.727

6.  Structure and Properties of La(2)O(3)-TiO(2) Nanocomposite Films for Biomedical Applications.

Authors:  Lin Zhang; Zhi-Hua Sun; Feng-Mei Yu; Hong-Bin Chen
Journal:  Bioinorg Chem Appl       Date:  2011-11-22       Impact factor: 7.778

7.  Characterization of Porous TiO2 Surfaces Formed on 316L Stainless Steel by Plasma Electrolytic Oxidation for Stent Applications.

Authors:  Zhiguang Huan; Lidy E Fratila-Apachitei; Iulian Apachitei; Jurek Duszczyk
Journal:  J Funct Biomater       Date:  2012-05-11
  7 in total