Literature DB >> 9737518

Spiral computed tomography: a novel diagnostic approach for investigation of the extracranial cerebral arteries and its complementary role in duplex ultrasonography.

R Corti1, C Ferrari, M Roberti, M Alerci, P L Pedrazzi, A Gallino.   

Abstract

BACKGROUND: For the detection of atherosclerotic lesions of the extracranial cerebral arteries, duplex ultrasonography (US) is an established operator-dependent method, whereas arteriography is associated with the not-insignificant risk of embolic complications. Spiral CT is a promising novel diagnostic tool that allows noninvasive, operator-independent diagnosis of obstruction of extracranial cerebral arteries. The aim of our prospective study was to evaluate in a clinical setting the complementary role of duplex US and spiral CT. METHODS AND
RESULTS: We compared the results obtained independently by spiral CT and duplex US in 59 consecutive patients with clinical suspicion of an obstructive lesion affecting the carotid arteries. We analyzed a total of 354 segments from the extracranial carotid arteries, including the common, internal, and external carotid arteries. A total of 4 complete occlusions, 38 severe stenoses (70% to 99%), and 32 moderate stenoses (30% to 69%) were concordantly identified by means of duplex US and spiral CT. In 5 cases in which duplex US did not allow sufficient evaluation of the carotid artery because of a poor US window or severe calcification, spiral CT allowed identification and correct measurement of the stenotic lesion. The comparison of the percentage of stenosis with both methods was good (r=0.91, P=0.024).
CONCLUSIONS: Our results indicate that spiral CT of the extracranial cerebral arteries is a promising noninvasive complementary and non-operator-dependent examination. Its application is particularly attractive in cases in which duplex US is not reliable (ie, severe kinking, severe calcification, short neck, and high bifurcation) and particularly when an overall view of the vascular field is required.

Entities:  

Mesh:

Year:  1998        PMID: 9737518     DOI: 10.1161/01.cir.98.10.984

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  3 in total

1.  Noninvasive in vivo measurement of vascular inflammation with F-18 fluorodeoxyglucose positron emission tomography.

Authors:  Ahmed Tawakol; Raymond Q Migrino; Udo Hoffmann; Suhny Abbara; Stuart Houser; Henry Gewirtz; James E Muller; Thomas J Brady; Alan J Fischman
Journal:  J Nucl Cardiol       Date:  2005 May-Jun       Impact factor: 5.952

Review 2.  Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.

Authors:  Nicolle Cassola; Jose Cc Baptista-Silva; Luis Cu Nakano; Carolina Dq Flumignan; Ricardo Sesso; Vladimir Vasconcelos; Nelson Carvas Junior; Ronald Lg Flumignan
Journal:  Cochrane Database Syst Rev       Date:  2022-07-11

3.  Efficacy and sensitivity of axial scans and different reconstruction methods in the study of the ulcerated carotid plaque using multidetector-row CT angiography: comparison with surgical results.

Authors:  L Saba; G Caddeo; R Sanfilippo; R Montisci; G Mallarini
Journal:  AJNR Am J Neuroradiol       Date:  2007-04       Impact factor: 3.825

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.