Panoramic dental radiography using a charge-coupled device receptor.

A G Farman1, T T Farman.   

Abstract

Panoramic radiography using a slit beam and film/screen receptor is standard for the emergency room evaluation of mandibular fractures and also in dentistry. This study compared the spatial resolution, area distortion factors, and the dosage considerations for a panoramic system where standard film/screen and a charge-coupled device were alternatively employed as the image receptor. Resolution and image contours were determined using a lead resolution grid positioned at selected beam projection angulations. Exposure measurements were carried out using a RANDO average man phantom and a 3 cc beryllium-windowed ionization chamber. The maximum spatial resolution with film approached 5 lp mm-1 whereas with the CCD the maximum resolution was just above 4 lp mm-1. Consequently, the image layer was reduced slightly in width when using the CCD receptor. The use of the CCD resulted in skin exposure reduction exceeding 70%.

Entities:  

Mesh:

Year:  1998        PMID: 9735460      PMCID: PMC3453417          DOI: 10.1007/bf03168293

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  7 in total

Review 1.  Digital radiology in dental diagnosis: a critical view.

Authors:  H G Gröndahl
Journal:  Dentomaxillofac Radiol       Date:  1992-11       Impact factor: 2.419

2.  The OP 100 Digipan: evaluation of the image layer, magnification factors, and dosimetry.

Authors:  T T Farman; M S Kelly; A G Farman
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1997-02

3.  Comparison of focal trough dimensions and form by resolution measurements in panoramic radiography.

Authors:  S Martinez-Cruz; L R Manson-Hing
Journal:  J Am Dent Assoc       Date:  1987-05       Impact factor: 3.634

4.  Angular measurements in orthopantomography.

Authors:  A Frykholm; O Malmgren; K A Sämfors; U Welander
Journal:  Dentomaxillofac Radiol       Date:  1977       Impact factor: 2.419

5.  Area distortion in narrow beam rotation radiography.

Authors:  K A Sämfors; U Welander
Journal:  Acta Radiol Diagn (Stockh)       Date:  1974-11

6.  Digital radiology. Facts and fictions.

Authors:  S M Dunn; M L Kantor
Journal:  J Am Dent Assoc       Date:  1993-12       Impact factor: 3.634

7.  Image distortion in rotational panoramic radiography. III. Inclined objects.

Authors:  G Tronje; U Welander; W D McDavid; C R Morris
Journal:  Acta Radiol Diagn (Stockh)       Date:  1981
  7 in total
  1 in total

1.  Changing trabecular patterns in panoramic radiographs of Swedish women during 25 years of follow-up.

Authors:  Wil Gm Geraets; Grethe Jonasson; Magnus Hakeberg
Journal:  Dentomaxillofac Radiol       Date:  2020-04-01       Impact factor: 2.419

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.