Literature DB >> 9735424

Enterprise-scale image distribution with a Web PACS.

A Gropper1, S Doyle, K Dreyer.   

Abstract

The integration of images with existing and new health care information systems poses a number of challenges in a multi-facility network: image distribution to clinicians; making DICOM image headers consistent across information systems; and integration of teleradiology into PACS. A novel, Web-based enterprise PACS architecture introduced at Massachusetts General Hospital provides a solution. Four AMICAS Web/Intranet Image Servers were installed as the default DICOM destination of 10 digital modalities. A fifth AMICAS receives teleradiology studies via the Internet. Each AMICAS includes: a Java-based interface to the IDXrad radiology information system (RIS), a DICOM autorouter to tape-library archives and to the Agfa PACS, a wavelet image compressor/decompressor that preserves compatibility with DICOM workstations, a Web server to distribute images throughout the enterprise, and an extensible interface which permits links between other HIS and AMICAS. Using wavelet compression and Internet standards as its native formats, AMICAS creates a bridge to the DICOM networks of remote imaging centers via the Internet. This teleradiology capability is integrated into the DICOM network and the PACS thereby eliminating the need for special teleradiology workstations. AMICAS has been installed at MGH since March of 1997. During that time, it has been a reliable component of the evolving digital image distribution system. As a result, the recently renovated neurosurgical ICU will be filmless and use only AMICAS workstations for mission-critical patient care.

Entities:  

Mesh:

Year:  1998        PMID: 9735424      PMCID: PMC3453358          DOI: 10.1007/bf03168249

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  5 in total

1.  Effects of a large-scale deployment of soft-copy devices for picture archiving and communication systems viewing.

Authors:  J C Honeyman; D Smith; V V Velocci
Journal:  J Digit Imaging       Date:  2000-05       Impact factor: 4.056

2.  Evaluation of a filmless radiology pilot--a preliminary report.

Authors:  C G Mast; M A Caruso; C S Gadd; H J Lowe
Journal:  Proc AMIA Symp       Date:  2001

3.  Performance of Web-based image distribution: client-oriented measurements.

Authors:  B Bergh; M Pietsch; A Schlaefke; T J Vogl
Journal:  Eur Radiol       Date:  2003-04-01       Impact factor: 5.315

4.  Performance of Web-based image distribution: server-oriented measurements.

Authors:  B Bergh; M Pietsch; A Schlaefke; I Garcia; T J Vogl
Journal:  Eur Radiol       Date:  2003-04-12       Impact factor: 5.315

5.  Technologies for image distribution in hospitals.

Authors:  Elmar Kotter; Tobias Baumann; Dieter Jäger; Mathias Langer
Journal:  Eur Radiol       Date:  2006-03-10       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.