Literature DB >> 9729869

Generation of third-order spherical and coma aberrations by use of radically symmetrical fourth-order lenses.

N López-Gil1, H C Howland, B Howland, N Charman, R Applegate.   

Abstract

We have extended the method of Alvarez [J. Am. Optom. Assoc. 49, 24 (1978)] to generate a variable magnitude of third-order spherical and/or coma aberration by using a combination of fourth-order plates with a magnification system. The technique, based on the crossed-cylinder aberroscope, is used to measure the wave-front aberration generated by the plates. The method has been applied to correct the third-order spherical aberration generated by an artificial eye as well as the coma produced by a progressive addition ophthalmic lens. The simplicity of the method and its relatively low cost make it attractive for partial correction of the aberrations of the eye.

Entities:  

Mesh:

Year:  1998        PMID: 9729869     DOI: 10.1364/josaa.15.002563

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  6 in total

1.  The change in internal aberrations following myopic corneal laser refractive surgery.

Authors:  Colm McAlinden; Jonathan E Moore
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-07-31       Impact factor: 3.117

2.  Change in visual acuity is well correlated with change in image-quality metrics for both normal and keratoconic wavefront errors.

Authors:  Ayeswarya Ravikumar; Jason D Marsack; Harold E Bedell; Yue Shi; Raymond A Applegate
Journal:  J Vis       Date:  2013-11-26       Impact factor: 2.240

3.  Optical quality of aspheric toric intraocular lenses at different degrees of decentering.

Authors:  Cari Pérez-Vives; Teresa Ferrer-Blasco; David Madrid-Costa; Santiago García-Lázaro; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-04-22       Impact factor: 3.117

4.  Aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses.

Authors:  Qing Yu; Jiang-Xiu Wu; He-Ning Zhang; Sheng Ye; Shi-Qi Dong; Chen-Hao Zhang
Journal:  Int J Ophthalmol       Date:  2013-04-18       Impact factor: 1.779

5.  Higher-order aberrations when wearing sphere and toric soft contact lenses.

Authors:  David A Berntsen; Mohinder M Merchea; Kathryn Richdale; Carla J Mack; Joseph T Barr
Journal:  Optom Vis Sci       Date:  2009-02       Impact factor: 1.973

Review 6.  In vivo optical quality of posterior-chamber phakic implantable collamer lenses with a central port.

Authors:  Robert Montés-Micó; Francisco Pastor-Pascual; Enrique Artiaga-Elordi; Ramón Ruiz-Mesa; Pedro Tañá-Rivero
Journal:  Eye Vis (Lond)       Date:  2021-08-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.