Literature DB >> 9727714

Exhaled isoprene and acetone in newborn infants and in children with diabetes mellitus.

N Nelson1, V Lagesson, A R Nosratabadi, J Ludvigsson, C Tagesson.   

Abstract

A new analytical method gas chromatography combined with UV spectrophotometry was used to measure isoprene and acetone in expired breath collected from four different groups of children: 1) healthy newborn babies, 2) healthy preschool children, 3) healthy school children, and 4) diabetic children in different metabolic states. Both isoprene and acetone could readily be determined in one single analysis of a 250-mL air sample. Newborn babies during the first postnatal week had undetectable or very low levels of isoprene in their expired air irrespective of catabolic or anabolic state. Breath isoprene increased with age, and healthy school children had higher levels than did healthy preschool children. No significant differences in breath isoprene were found between healthy and diabetic children. Breath acetone was found to correlate with metabolic state both in newborn babies and in diabetic children. These findings illustrate the potential use of a new technique for breath analysis in children with metabolic disturbances.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9727714     DOI: 10.1203/00006450-199809000-00016

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  8 in total

1.  Improved predictive models for plasma glucose estimation from multi-linear regression analysis of exhaled volatile organic compounds.

Authors:  Jane Lee; Jerry Ngo; Don Blake; Simone Meinardi; Andria M Pontello; Robert Newcomb; Pietro R Galassetti
Journal:  J Appl Physiol (1985)       Date:  2009-05-07

Review 2.  Breath tests in respiratory and critical care medicine: from research to practice in current perspectives.

Authors:  Attapon Cheepsattayakorn; Ruangrong Cheepsattayakorn
Journal:  Biomed Res Int       Date:  2013-09-18       Impact factor: 3.411

3.  A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management.

Authors:  Chenyu Jiang; Meixiu Sun; Zhennan Wang; Zhuying Chen; Xiaomeng Zhao; Yuan Yuan; Yingxin Li; Chuji Wang
Journal:  Sensors (Basel)       Date:  2016-07-30       Impact factor: 3.576

Review 4.  Significance of Exhaled Breath Test in Clinical Diagnosis: A Special Focus on the Detection of Diabetes Mellitus.

Authors:  Souvik Das; Saurabh Pal; Madhuchhanda Mitra
Journal:  J Med Biol Eng       Date:  2016-10-11       Impact factor: 1.553

5.  Indium Nitrite (InN)-Based Ultrasensitive and Selective Ammonia Sensor Using an External Silicone Oil Filter for Medical Application.

Authors:  Sujeet Kumar Rai; Kun-Wei Kao; Shanjgr Gwo; Ashish Agarwal; Wei Da Lin; J Andrew Yeh
Journal:  Sensors (Basel)       Date:  2018-11-11       Impact factor: 3.576

6.  Deficiency and absence of endogenous isoprene in adults, disqualified its putative origin.

Authors:  Pritam Sukul; Anna Richter; Jochen K Schubert; Wolfram Miekisch
Journal:  Heliyon       Date:  2021-01-12

Review 7.  Hyphenated Mass Spectrometry versus Real-Time Mass Spectrometry Techniques for the Detection of Volatile Compounds from the Human Body.

Authors:  Oliver Gould; Natalia Drabińska; Norman Ratcliffe; Ben de Lacy Costello
Journal:  Molecules       Date:  2021-11-26       Impact factor: 4.411

8.  Non-Invasive Assessment of Metabolic Adaptation in Paediatric Patients Suffering from Type 1 Diabetes Mellitus.

Authors:  Phillip Trefz; Sibylle C Schmidt; Pritam Sukul; Jochen K Schubert; Wolfram Miekisch; Dagmar-Christiane Fischer
Journal:  J Clin Med       Date:  2019-10-26       Impact factor: 4.241

  8 in total