Literature DB >> 9725561

Comparison of two flow cytometric methods enumerating CD4 T cells and CD8 T cells.

J Storek1, M A Dawson, D G Maloney.   

Abstract

The enumeration of blood CD4+ (single-positive) T cells by flow cytometry is subject to errors such as counting CD4+ monocytes or CD4+CD8+ (double-positive) T cells as CD4+ T cells. Relatively accurate count can be obtained when CD4+ T cells are defined as CD3+CD4+CD8- mononuclear cells (MNCs), using 3-color flow cytometry. However, using this approach, further classification into CD4+ T cell subsets requires expensive 4-color flow cytometry. In an attempt to enumerate CD4+ T cells using only 2 colors, we have defined CD4+ T cells as MNCs expressing CD4 and not expressing the markers of other MNCs (CD8, CD13, CD14, and CD16) and compared the results to those obtained with the 3-color method in which CD4+ T cells were defined as CD3+CD4+CD8- MNCs. Both methods produced similar results. An analogous approach was undertaken to enumerate CD8+ T cells as MNCs expressing CD8 and not expressing the markers of other MNCs. However, when compared with the percents obtained by the 3-color method in which CD8+ T cells were defmed as CD3+CD4-CD8+ MNCs, the 2-color method overestimated the percent of CD8+ T cells. This was likely due to counting CD8low null cells as CD8+ T cells. When the percentages of CD8high T cells were evaluated, both methods produced similar results. We conclude that the 2-color method is suitable for the enumeration of CD4+ T cells and CD8high T cells and reserves the third color for further enumeration of CD4+ or CD8high T cell subsets.

Entities:  

Mesh:

Year:  1998        PMID: 9725561     DOI: 10.1002/(sici)1097-0320(19980901)33:1<76::aid-cyto9>3.0.co;2-9

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  4 in total

1.  High-dose immunosuppressive therapy for severe systemic sclerosis: initial outcomes.

Authors:  Peter A McSweeney; Richard A Nash; Keith M Sullivan; Jan Storek; Leslie J Crofford; Roger Dansey; Maureen D Mayes; Kevin T McDonagh; J Lee Nelson; Theodore A Gooley; Leona A Holmberg; C S Chen; Mark H Wener; Katherine Ryan; Julie Sunderhaus; Ken Russell; John Rambharose; Rainer Storb; Daniel E Furst
Journal:  Blood       Date:  2002-09-01       Impact factor: 22.113

2.  Effects of ovarian steroids on immunoglobulin-secreting cell function in healthy women.

Authors:  Fabien X Lü; Zhongmin Ma; Susie Moser; Thomas G Evans; Christopher J Miller
Journal:  Clin Diagn Lab Immunol       Date:  2003-09

3.  Normative data for flow cytometry immunophenotyping of benign lymph nodes sampled by surgical biopsy.

Authors:  Gregory David Scott; Susan K Atwater; Dita A Gratzinger
Journal:  J Clin Pathol       Date:  2017-09-15       Impact factor: 3.411

4.  Flow immunophenotyping of benign lymph nodes sampled by FNA: Representative with diagnostic pitfalls.

Authors:  Gregory D Scott; Hubert D Lau; Jason H Kurzer; Christina S Kong; Dita A Gratzinger
Journal:  Cancer Cytopathol       Date:  2018-09-07       Impact factor: 5.284

  4 in total