Literature DB >> 9714117

Asynchronous electrical activation induces asymmetrical hypertrophy of the left ventricular wall.

M F van Oosterhout1, F W Prinzen, T Arts, J J Schreuder, W Y Vanagt, J P Cleutjens, R S Reneman.   

Abstract

BACKGROUND: Asynchronous electrical activation, induced by ventricular pacing, causes regional differences in workload, which is lower in early- than in late-activated regions. Because the myocardium usually adapts its mass and structure to altered workload, we investigated whether ventricular pacing leads to inhomogeneous hypertrophy and whether such adaptation, if any, affects global left ventricular (LV) pump function. METHODS AND
RESULTS: Eight dogs were paced at physiological heart rate for 6 months (AV sequential, AV interval 25 ms, ventricular electrode at the base of the LV free wall). Five dogs were sham operated and served as controls. Ventricular pacing increased QRS duration from 47.2+/-10.6 to 113+/-16.5 ms acutely and to 133.8+/-25.2 ms after 6 months. Two-dimensional echocardiographic measurements showed that LV cavity and wall volume increased significantly by 27+/-15% and 15+/-17%, respectively. The early-activated LV free wall became significantly (17+/-17%) thinner, whereas the late-activated septum thickened significantly (23+/-12%). Calculated sector volume did not change in the LV free wall but increased significantly in the septum by 39+/-13%. In paced animals, cardiomyocyte diameter was significantly (18+/-7%) larger in septum than in LV free wall, whereas myocardial collagen fraction was unchanged in both areas. LV pressure-volume analysis showed that ventricular pacing reduced LV function to a similar extent after 15 minutes and 6 months of pacing.
CONCLUSIONS: Asynchronous activation induces asymmetrical hypertrophy and LV dilatation. Cardiac pump function is not affected by the adaptational processes. These data indicate that local cardiac load regulates local cardiac mass of both myocytes and collagen.

Entities:  

Mesh:

Year:  1998        PMID: 9714117     DOI: 10.1161/01.cir.98.6.588

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  79 in total

Review 1.  Developing clinical indication for multisite pacing.

Authors:  L Kappenberger; X Lyon; N Cox; G Girod; J Schlaepfer
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

Review 2.  The mechanical and metabolic basis of myocardial blood flow heterogeneity.

Authors:  J B Bassingthwaighte; D A Beard; Z Li
Journal:  Basic Res Cardiol       Date:  2001-11       Impact factor: 17.165

3.  Mapping of regional myocardial strain and work during ventricular pacing: experimental study using magnetic resonance imaging tagging.

Authors:  F W Prinzen; W C Hunter; B T Wyman; E R McVeigh
Journal:  J Am Coll Cardiol       Date:  1999-05       Impact factor: 24.094

Review 4.  Cellular electrophysiological abnormalities in dyssynchronous hearts and during CRT.

Authors:  Marc Vanderheyden; Martin Penicka; Jozef Bartunek
Journal:  J Cardiovasc Transl Res       Date:  2011-12-07       Impact factor: 4.132

Review 5.  The molecular fingerprint of cardiac dyssynchrony and cardiac resynchronization therapy.

Authors:  Marc Vanderheyden; Chris Vrints; Jozef Bartunek
Journal:  Heart Fail Rev       Date:  2011-05       Impact factor: 4.214

6.  Comparison of the acute hemodynamic effect of right ventricular apex, outflow tract, and dual-site right ventricular pacing.

Authors:  Andrzej Rubaj; Piotr Rucinski; Tomasz Sodolski; Andrzej Bilan; Marcin Gulaj; Alicja Dabrowska-Kugacka; Andrzej Kutarski
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-10       Impact factor: 1.468

7.  Permanent direct his bundle pacing does not induce ventricular dyssynchrony unlike conventional right ventricular apical pacing. An intrapatient acute comparison study.

Authors:  Domenico Catanzariti; Massimiliano Maines; Claudio Cemin; Gianpaolo Broso; Tiziana Marotta; Giuseppe Vergara
Journal:  J Interv Card Electrophysiol       Date:  2006-11-18       Impact factor: 1.900

8.  Computational cardiac anatomy using MRI.

Authors:  Mirza Faisal Beg; Patrick A Helm; Elliot McVeigh; Michael I Miller; Raimond L Winslow
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

9.  Electromechanics of paced left ventricle simulated by straightforward mathematical model: comparison with experiments.

Authors:  R C P Kerckhoffs; O P Faris; P H M Bovendeerd; F W Prinzen; K Smits; E R McVeigh; T Arts
Journal:  Am J Physiol Heart Circ Physiol       Date:  2005-06-17       Impact factor: 4.733

Review 10.  Right ventricular outflow tract pacing: not ready for prime-time.

Authors:  S Serge Barold; Bengt Herweg
Journal:  J Interv Card Electrophysiol       Date:  2005-06       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.