Literature DB >> 9713763

Effect of chemical sanitizing agents on ATP bioluminescence measurements.

T A Green1, S M Russell, D L Fletcher.   

Abstract

Experiments were conducted to determine the effects of sodium hypochlorite (SH), quaternary ammonium (QA), trisodium phosphate (TSP), lactic acid (LA), hydrogen peroxide (HP), and trichlosan (TR) on ATP bioluminescence measurements. Each sanitizer was tested at three different levels and compared to a control group containing no sanitizer. ATP from three sources was analyzed, Escherichia coli, chicken blood, and a pure ATP standard. The effect of each sanitizer was reported as a percent decrease in log10 relative light units (LRLU) for the treatment groups when compared to LRLU from the control groups. SH concentrations of 30, 50, and 70 ppm and quaternary ammonium at concentrations of 10, 20, and 30 ppm had no effect on LRLU measurements, regardless of the ATP source. LA concentrations of 0.5% and higher reduced LRLU by 75%. LRLU measurements were significantly (P < or = 0.05) reduced by approximately 60% when levels of TSP exceeded 1%. HP had no effect on LRLU measurements from any of the ATP sources at 0.1%; however, at 1% HP significantly (P < or = 0.05) decreased LRLU measurements by approximately 60% for all ATP sources. TR at 0.25% had no significant effect on LRLU measurements from any of the ATP sources. TR at 0.5 and 1% reduced LRLU measurements by 30 and 50%, respectively. These results indicate that commercial sanitizers containing LA, TSP, HP, or TR may negatively affect LRLU measurements if the sanitizer is allowed to come into direct contact with the ATP bioluminescence reagents.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9713763     DOI: 10.4315/0362-028x-61.8.1013

Source DB:  PubMed          Journal:  J Food Prot        ISSN: 0362-028X            Impact factor:   2.077


  4 in total

1.  Adenosine triphosphate bioluminescence assay for monitoring contamination of the working environment of anaesthetists and cleanliness of the operating room.

Authors:  Tomoko Fukada; Yuri Tsuchiya; Hiroko Iwakiri; Makoto Ozaki
Journal:  J Infect Prev       Date:  2014-11-13

2.  Assessment of percent positive agreement between fluorescent marker and ATPase for environmental cleaning monitoring during sequential application in an intensive care unit.

Authors:  Jason P Burnham; Emily R Shives; David K Warren; Jennifer H Han; Hilary M Babcock
Journal:  Am J Infect Control       Date:  2019-11-16       Impact factor: 2.918

3.  Evaluation of Rodent Cage Processing Using Reduced Water Temperatures.

Authors:  Mary M Walker; Dianne M Harrison; Toi A Collins; Valerie K Bergdall
Journal:  J Am Assoc Lab Anim Sci       Date:  2021-06-28       Impact factor: 1.706

4.  How reliable are ATP bioluminescence meters in assessing decontamination of environmental surfaces in healthcare settings?

Authors:  Navid Omidbakhsh; Faraz Ahmadpour; Nicole Kenny
Journal:  PLoS One       Date:  2014-06-18       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.