Changes in oxygen saturation and transcutaneous carbon dioxide and oxygen levels in patients undergoing fibreoptic bronchoscopy.

E N Evans, K Ganeshalingam, P Ebden.   

Abstract

Patients undergoing bronchoscopy are usually monitored with pulse oximetry to measure arterial oxygen saturation, but this can fail to detect hypoventilation, particularly if added inspired oxygen is used. Transcutaneous oxygen and carbon dioxide tensions can be measured; the later reflecting respiratory drive. We compared transcutaneous PO2 and PCO2 values with oxygen saturation in patients undergoing day-case bronchoscopy, to see if this information would further improve the safety of the bronchoscopic procedure. Twenty-two consecutive patients undergoing routine fibreoptic bronchoscopy (15 male, mean age 62.3 years; range 45-82 years), were studied using pulse oximetry (OXImeter, Radiometer) and transcutaneous PCO2/PO2 monitoring (TCM3, TINA, Radiometer). We documented a statistically significant increase in transcutaneous PCO2 from mean (SD) stable baseline levels of 5.8 (0.3) kPa (range 4.2-7.9 kPa) to mean peak levels during bronchoscopy of 7.0 (1.0) kPa (range 5.0-8.7 kPa). The time to first adverse change in transcutaneous PCO2 (P = 0.046) and PO2 (P = 0.035) occurred more rapidly than reduction in oxygen saturation in 19 of the 22 cases; median times for change in PCO2 of 67 s (range 10-1800 s), PO2 of 120 s (range 26-559 s) and oxygen saturation of 174 s (range 43-1332 s), timed from administration of i.v. sedation prior to each bronchoscopy. Transcutaneous PCO2/PO2 monitoring during fibreoptic bronchoscopy provided evidence of hypoventilation with significantly elevated levels of transcutaneous PCO2. This method of monitoring provides an earlier indication of respiratory depression during fibreoptic bronchoscopy compared with pulse oximetry.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9713633     DOI: 10.1016/s0954-6111(98)90005-1

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  4 in total

1.  British Thoracic Society guidelines on diagnostic flexible bronchoscopy.

Authors: 
Journal:  Thorax       Date:  2001-03       Impact factor: 9.139

2.  Significant Delay in the Detection of Desaturation between Finger Transmittance and Earlobe Reflectance Oximetry Probes during Fiberoptic Bronchoscopy: Analysis of 104 Cases.

Authors:  Barak Pertzov; Elitsur Brachfeld; Avraham Unterman; Evgeni Gershman; Nader Abdel-Rahman; Dror Rosengarten; Mordechai Reuven Kramer
Journal:  Lung       Date:  2018-11-24       Impact factor: 2.584

3.  Carbon dioxide monitoring during laparoscopic-assisted bariatric surgery in severely obese patients: transcutaneous versus end-tidal techniques.

Authors:  Joanna M Dion; Chris McKee; Joseph D Tobias; Daniel Herz; Paul Sohner; Steven Teich; Marc Michalsky
Journal:  J Clin Monit Comput       Date:  2014-06-11       Impact factor: 2.502

4.  Guidelines on analgosedation, monitoring, and recovery time for flexible bronchoscopy: a systematic review.

Authors:  Daniel Strohleit; Thomas Galetin; Nils Kosse; Alberto Lopez-Pastorini; Erich Stoelben
Journal:  BMC Pulm Med       Date:  2021-06-10       Impact factor: 3.317

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.