Literature DB >> 9702944

Evaluating stat testing options in an academic health center: therapeutic turnaround time and staff satisfaction.

M L Kilgore1, S J Steindel, J A Smith.   

Abstract

We compared centralized vs distributed methods for delivering "stat" test results for blood gas, glucose, and electrolyte assays. The parameters for comparison were as follows: (a) laboratory turnaround time (TAT), (b) therapeutic TAT, and (c) staff satisfaction. Therapeutic TAT, defined as the time from the initiating order to the receipt of the result and the implementation of any indicated change in treatment, was obtained by direct observation of testing procedures at the bedside and timing each step in the process. Observing therapeutic TAT yields information on the impact of laboratory testing methods in the context of clinical decision making. Therapeutic TAT was 1-2 min shorter for bedside testing compared with a satellite laboratory and 9-14 min shorter in the satellite laboratory compared with centralized testing. Satellite laboratories received the highest staff satisfaction scores, followed by bedside testing, with the central laboratory receiving the lowest scores.

Entities:  

Mesh:

Year:  1998        PMID: 9702944

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  15 in total

Review 1.  Point-of-care testing in hospitals and primary care.

Authors:  Ralf Junker; Harald Schlebusch; Peter B Luppa
Journal:  Dtsch Arztebl Int       Date:  2010-08-20       Impact factor: 5.594

Review 2.  Point-of-care blood glucose testing for diabetes care in hospitalized patients: an evidence-based review.

Authors:  Rajesh Rajendran; Gerry Rayman
Journal:  J Diabetes Sci Technol       Date:  2014-06-05

3.  Silicon nanowires with high-k hafnium oxide dielectrics for sensitive detection of small nucleic acid oligomers.

Authors:  Brian R Dorvel; Bobby Reddy; Jonghyun Go; Carlos Duarte Guevara; Eric Salm; Muhammad Ashraful Alam; Rashid Bashir
Journal:  ACS Nano       Date:  2012-06-22       Impact factor: 15.881

Review 4.  Blood glucose measurement in the intensive care unit: what is the best method?

Authors:  Huong T Le; Neil S Harris; Abby J Estilong; Arvid Olson; Mark J Rice
Journal:  J Diabetes Sci Technol       Date:  2013-03-01

5.  Impact of glucose measurement processing delays on clinical accuracy and relevance.

Authors:  Sujit R Jangam; Gary Hayter; Timothy C Dunn
Journal:  J Diabetes Sci Technol       Date:  2013-05-01

Review 6.  Mapping turnaround times (TAT) to a generic timeline: a systematic review of TAT definitions in clinical domains.

Authors:  Bernhard Breil; Fleur Fritz; Volker Thiemann; Martin Dugas
Journal:  BMC Med Inform Decis Mak       Date:  2011-05-24       Impact factor: 2.796

Review 7.  Detecting Tumor Metastases: The Road to Therapy Starts Here.

Authors:  M E Menezes; S K Das; I Minn; L Emdad; X-Y Wang; D Sarkar; M G Pomper; P B Fisher
Journal:  Adv Cancer Res       Date:  2016-08-17       Impact factor: 6.242

Review 8.  Detecting circulating tumor cells: current challenges and new trends.

Authors:  Bin Hong; Youli Zu
Journal:  Theranostics       Date:  2013-04-23       Impact factor: 11.556

9.  Strategies for the successful implementation of viral laboratory automation.

Authors:  Cristóbal Avivar
Journal:  Open Virol J       Date:  2012-11-30

10.  Feasibility of performing multiple point of care testing for HIV anti-retroviral treatment initiation and monitoring from multiple or single fingersticks.

Authors:  Natasha Gous; Lesley Scott; Joachim Potgieter; Lumka Ntabeni; Sharon Enslin; Ronel Newman; Wendy Stevens
Journal:  PLoS One       Date:  2013-12-20       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.