Literature DB >> 9700846

A new quantitative D-dimer assay appropriate in emergency: reliability of the assay for pulmonary embolism exclusion diagnosis.

M Duet1, S Benelhadj, W Kedra, D Vilain, C Ajzenberg, D Elkharrat, L Drouet, C Soria, O Mundler.   

Abstract

Plasma D-dimers, degradation products of cross-linked fibrin, are elevated in several thrombotic diseases. In the last decade, their measurement has been performed with specific monoclonal antibody based ELISA assay, with a high negative predictive value of such pathologies. However these methods have a low clinical impact since they cannot be used in emergency because they are time consuming and require series. Recently, rapid tests have been proposed with similar accuracy and are feasible for use in emergency conditions. The aim of our study was to evaluate the potential value of a new quantitative rapid assay, based on agglutination of latex microparticles coated with two monoclonal antibodies specific for D-dimers (Liatest D-Di, Diagnostica Stago), in the exclusion diagnosis of pulmonary embolism (PE). Eighty-five consecutive suspected PE patients were included in the study. D-dimer determination was performed with both standard ELISA and Liatest D-Di just before pulmonary scintigraphy. Sixty-nine patients were free of PE and 16 had PE. Our results confirm the excellent sensitivity and negative predictive values of the conventional D-dimer ELISA. Using a cut-off value of 500 ng/ml, the sensitivity and the negative predictive values of Liatest D-Di were 94% and 96%, respectively. Only one case of PE had a D-dimer value at 480 ng/ml, close to the cut-off value. This study demonstrates that the Liatest D-Di assay is sensitive enough to be used as the first step in the assessment of PE. However, the best cut-off value has to be determined to get an exclusion diagnosis with certainty.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9700846     DOI: 10.1016/s0049-3848(98)00048-6

Source DB:  PubMed          Journal:  Thromb Res        ISSN: 0049-3848            Impact factor:   3.944


  9 in total

Review 1.  Rapid D-dimer testing as an adjunct to clinical findings in excluding pulmonary embolism.

Authors:  A F Lennox; A N Nicolaides
Journal:  Thorax       Date:  1999-08       Impact factor: 9.139

2.  Association between plasma levels of D-dimer and fibrinogen/fibrin degradation products (FDP) for exclusion of thromboembolic disorders.

Authors:  Rafael Noal Moresco; Ronald Halla Júnior; Luis Cláudio Rosa Vargas; Lúcia Mariano da Rocha Silla
Journal:  J Thromb Thrombolysis       Date:  2006-04       Impact factor: 2.300

3.  Lack of association between cardiac troponin T and D-dimer in the evaluation of myocardial damage.

Authors:  Rafael Noal Moresco; Luís Cláudio Rosa Vargas; Ronald Halla Júnior; Lúcia Mariano da Rocha Silla
Journal:  J Clin Lab Anal       Date:  2005       Impact factor: 2.352

Review 4.  D-dimer testing: the role of the clinical laboratory in the diagnosis of pulmonary embolism.

Authors:  B H Mavromatis; C M Kessler
Journal:  J Clin Pathol       Date:  2001-09       Impact factor: 3.411

5.  Cost-effectiveness of strategies for diagnosing pulmonary embolism among emergency department patients presenting with undifferentiated symptoms.

Authors:  Ram S Duriseti; Margaret L Brandeau
Journal:  Ann Emerg Med       Date:  2010-06-03       Impact factor: 5.721

6.  D-dimer and its relationship to fibrinogen/fibrin degradation products (FDPs) in disorders associated with activation of coagulation or fibrinolytic systems.

Authors:  Rafael Noal Moresco; Luis Cláudio Rosa Vargas; Carlos Franco Voegeli; Roberto Christ Vianna Santos
Journal:  J Clin Lab Anal       Date:  2003       Impact factor: 2.352

7.  Functional production and characterization of a fibrin-specific single-chain antibody fragment from Bacillus subtilis: effects of molecular chaperones and a wall-bound protease on antibody fragment production.

Authors:  Sau-Ching Wu; Jonathan C Yeung; Yanjun Duan; Ruiqiong Ye; Steven J Szarka; Hamid R Habibi; Sui-Lam Wong
Journal:  Appl Environ Microbiol       Date:  2002-07       Impact factor: 4.792

8.  Estimation of the levels of D-dimer by use of an alternative method based in the reaction time of fibrinogen/fibrin degradation products assay.

Authors:  Rafael Noal Moresco; Luis Cláudio Rosa Vargas; Lúcia Silla
Journal:  J Thromb Thrombolysis       Date:  2006-12-09       Impact factor: 5.221

9.  New combinational assay using soluble fibrin and d-dimer determinations: a promising strategy for identifying patients with suspected venous thromboembolism.

Authors:  Shahsoltan Mirshahi; Claudine Soria; Basile Kouchakji; Gérald Kierzek; Jeanne Yvonne Borg; Rémi Varin; Jean Chidiac; Ludovic Drouet; Massoud Mirshahi; Jeannette Soria
Journal:  PLoS One       Date:  2014-03-24       Impact factor: 3.240

  9 in total