Literature DB >> 9698966

Waste gas exposure during desflurane and isoflurane anaesthesia.

J Hobbhahn1, K Hoerauf, G Wiesner, K Schrögendorfer, K Taeger.   

Abstract

BACKGROUND: Currently, there are no data available concerning the occupational exposure to desflurane during general anaesthesia. This prospective, randomized study reports on occupational exposure to desflurane, compared to isoflurane, in a modern operation theatre (OT).
METHODS: The study was performed in an OT equipped with a modern air-conditioning system and with a low-leakage anaesthesia machine connected to a central scavenging system. Trace concentrations of the anaesthetics were measured continuously by means of a photoacoustic infrared spectrometer during general anaesthesia in 30 patients undergoing eye surgery. Values were obtained within the breathing zone of the anaesthetist, the surgeon, the auxiliary nurse and at the mouth of the patient.
RESULTS: Desflurane and isoflurane were administered with median (range) endtidal concentrations of 4.7 (3.8-10.3) vol% and 0.9 (0.6-1.4) vol%, respectively. The personnel-related median values of the average trace concentrations of desflurane and isoflurane were 0.5 (0.01-7.5) ppm and 0.2 (0.01-1.6) ppm, respectively.
CONCLUSIONS: Occupational exposure to desflurane is low in the environment of a modern OT, even though it has to be administered in approximately 5-fold higher concentrations compared to isoflurane.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9698966     DOI: 10.1111/j.1399-6576.1998.tb05335.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  4 in total

Review 1.  Occupational exposure to volatile anaesthetics: epidemiology and approaches to reducing the problem.

Authors:  C Byhahn; H J Wilke; K Westpphal
Journal:  CNS Drugs       Date:  2001       Impact factor: 5.749

2.  Surgeon's occupational exposure to nitrous oxide and sevoflurane during pediatric surgery.

Authors:  C Byhahn; K Heller; V Lischke; K Westphal
Journal:  World J Surg       Date:  2001-09       Impact factor: 3.352

3.  [Calibration of a room air gas monitor with certified reference gases].

Authors:  W A Krueger; M Trick; T H Schroeder; K E Unertl
Journal:  Anaesthesist       Date:  2003-12       Impact factor: 1.041

4.  Environmental and biological measurements of isoflurane and sevoflurane in operating room personnel.

Authors:  Abbas Jafari; Rogaieh Bargeshadi; Fatemeh Jafari; Iraj Mohebbi; Mohammad Hajaghazadeh
Journal:  Int Arch Occup Environ Health       Date:  2017-12-15       Impact factor: 3.015

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.