Literature DB >> 9689374

The effect of screw insertion torque on tendons fixed with spiked washers.

B D Beynnon1, C M Meriam, S H Ryder, B C Fleming, R J Johnson.   

Abstract

The long-term success of a hamstring tendon graft depends not only on the type of device that is used for fixation but also on the mechanical interlocking of the soft tissue between the fixation device and bone. The purpose of this study was to evaluate the effect of screw insertion torque on the structural properties of soft tissue fixed to bone with a spiked metal washer. Two bovine tendons, one similar in size to a human semitendinosus tendon and the other similar in size to a human gracilis tendon, were secured to a bovine femur using a figure-of-8 technique with screws and metal spiked washers. A single load to failure was applied at 25 mm/sec. A significant positive linear correlation was observed between fixation screw insertion torque magnitude and the ultimate failure load value. An increase in the fixation screw insertion torque produced an increase in the ultimate failure load value. Similarly, there was a significant positive linear correlation between fixation screw insertion torque magnitude and the average maximum linear load value. No relationship was detected between screw insertion torque magnitude and the linear stiffness values of the tendon-fixation construct, indicating that a reproducible model was used. This study demonstrates that screw insertion torque is an important variable that controls the initial strength of soft tissue fixation to bone.

Entities:  

Mesh:

Year:  1998        PMID: 9689374     DOI: 10.1177/03635465980260041101

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  3 in total

1.  Mechanoactive scaffold induces tendon remodeling and expression of fibrocartilage markers.

Authors:  Jeffrey P Spalazzi; Moira C Vyner; Matthew T Jacobs; Kristen L Moffat; Helen H Lu
Journal:  Clin Orthop Relat Res       Date:  2008-05-30       Impact factor: 4.176

2.  Biomechanical characteristics of an implant used to secure semitendinosus-gracilis tendon grafts in a canine model of extra-articular anterior cruciate ligament reconstruction.

Authors:  Mandi J Lopez; Nakia Spencer; John P Casey; William Todd Monroe
Journal:  Vet Surg       Date:  2007-08       Impact factor: 1.495

Review 3.  Orthopedic interface tissue engineering for the biological fixation of soft tissue grafts.

Authors:  Kristen L Moffat; I-Ning Elaine Wang; Scott A Rodeo; Helen H Lu
Journal:  Clin Sports Med       Date:  2009-01       Impact factor: 2.182

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.