OBJECTIVE: To compare initial femoral fixation properties of a new implant, Graftgrab (GG), with 2 established methods of extra-articular femoral graft fixation, spiked washers (SW) and bone staples (ST). STUDY
DESIGN: Experimental in vitro cohort study.
METHODS: Canine semitendinosus-gracilis tendon grafts were passed through bone tunnels and fixed to the lateral surface of femoral condyles with spiked washers, bone staples, or new implant prototypes. The fixations were tested to failure with a single-cycle load at a rate of 50 mm/min. Failure and yield strength, stiffness, energy, and elongation were determined from load-displacement curves and failure modes were recorded.
RESULTS: The graft failed midsubstance in 4 SW, 4 ST, and 1 GG fixations. In 3 SW, 3 ST, and 1 GG specimens, the graft slipped from the fixation. The graft ruptured at the clip (3) and the intra-articular (2) surface of the bone tunnel in the remaining GG specimens. There were no significant differences between fixation groups in femoral tunnel length, femoral width, or the mechanical properties evaluated.
CONCLUSIONS: The initial in vitro mechanical properties of the new fixation implant are comparable with those of spiked washers and bone staples. CLINICAL RELEVANCE: The initial mechanical performance of the new implant tested in this study was similar to those of comparable, established implants. The new implant is novel and may be useful for human anterior and veterinary cranial cruciate ligament graft reconstruction fixation.

Entities:  

Mesh:

Year:  2007        PMID: 17686135      PMCID: PMC2168393          DOI: 10.1111/j.1532-950X.2007.00310.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  14 in total

1.  Tendon healing in a bone tunnel. Part II: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep.

Authors:  Andreas Weiler; Reinhard F G Hoffmann; Hermann J Bail; Oliver Rehm; Norbert P Südkamp
Journal:  Arthroscopy       Date:  2002-02       Impact factor: 4.772

2.  Contributions of femoral fixation methods to the stiffness of anterior cruciate ligament replacements at implantation.

Authors:  J T To; S M Howell; M L Hull
Journal:  Arthroscopy       Date:  1999-05       Impact factor: 4.772

3.  The effect of screw insertion torque on tendons fixed with spiked washers.

Authors:  B D Beynnon; C M Meriam; S H Ryder; B C Fleming; R J Johnson
Journal:  Am J Sports Med       Date:  1998 Jul-Aug       Impact factor: 6.202

4.  The influence of tendon length and fit on the strength of a tendon-bone tunnel complex. A biomechanical and histologic study in the dog.

Authors:  P E Greis; R T Burks; K Bachus; M G Luker
Journal:  Am J Sports Med       Date:  2001 Jul-Aug       Impact factor: 6.202

5.  The effect of anterior cruciate ligament graft elongation at the time of implantation on the biomechanical behavior of the graft and knee.

Authors:  H Tohyama; B D Beynnon; R J Johnson; P A Renström; S W Arms
Journal:  Am J Sports Med       Date:  1996 Sep-Oct       Impact factor: 6.202

6.  A mechanical comparison of gluteus medius attachment methods in a canine model.

Authors:  M D Markel; M G Rock; D S Bergenthal; D R Young; R Vanderby; E Y Chao
Journal:  J Orthop Res       Date:  1993-05       Impact factor: 3.494

7.  Early tension loss in an anterior cruciate ligament graft. A cadaver study of four tibial fixation devices.

Authors:  Dustin M Grover; Stephen M Howell; Maury L Hull
Journal:  J Bone Joint Surg Am       Date:  2005-02       Impact factor: 5.284

8.  Experimental studies of acute anterior cruciate ligament injury and repair.

Authors:  H E Cabaud; W G Rodkey; J A Feagin
Journal:  Am J Sports Med       Date:  1979 Jan-Feb       Impact factor: 6.202

9.  Effects of graft rotation on initial biomechanical failure characteristics of bone-patellar tendon-bone constructs.

Authors:  Nikhil Verma; Mayo A Noerdlinger; Nadim Hallab; Charles A Bush-Joseph; Bernard R Bach
Journal:  Am J Sports Med       Date:  2003 Sep-Oct       Impact factor: 6.202

10.  Hamstring graft technique for stabilization of canine cranial cruciate ligament deficient stifles.

Authors:  Mandi J Lopez; Mark D Markel; Vicki Kalscheur; Yan Lu; Paul A Manley
Journal:  Vet Surg       Date:  2003 Jul-Aug       Impact factor: 1.495

View more
  2 in total

1.  In-vitro comparison of 3 knotting techniques for lateral fabellotibial suture stabilization.

Authors:  David L Dycus; Jennifer L Wardlaw; Dennis Rowe; Steve Elder
Journal:  Can Vet J       Date:  2013-04       Impact factor: 1.008

2.  Novel anterior cruciate ligament graft fixation device reduces slippage.

Authors:  Mandi J Lopez; Allen Borne; W Todd Monroe; Prakash Bommala; Laura Kelly; Nan Zhang
Journal:  Med Devices (Auckl)       Date:  2013-05-14