Literature DB >> 9687972

Comparison of dose-response curves for chromosomal aberrations established by chromosome painting and conventional analysis.

C Lindholm1, S Luomahaara, A Koivistoinen, T Ilus, A A Edwards, S Salomaa.   

Abstract

PURPOSE: To establish 60Co gamma-ray dose-response curves for dicentrics and translocations visualized by chromosome painting and for dicentrics analysed after conventional solid staining.
MATERIALS AND METHODS: Analysis of chromosomal aberrations was performed on peripheral blood lymphocytes obtained from 48 h old cultures of irradiated whole blood. Dicentrics were scored from Giemsa-stained preparations, and bi-coloured dicentrics and translocations after FISH painting of chromosomes 1, 2 and 4.
RESULTS: Equal frequencies of complete dicentrics and translocations, where both members of the exchanges were seen, were observed in the chromosome painting analysis at all doses, resulting in similar calibration curves. Due to differences in scoring criteria, dicentrics scored in conventionally Giemsa-stained slides agreed better with data for total than for complete exchanges. Donor differences for translocations at the control level and at low doses were seen and large uncertainty surrounds the linear component of the dose-response for total translocations.
CONCLUSIONS: Dose reconstruction of past exposures in cases of low doses is very dependent on the linear coefficient of the curve. Results indicate that total translocations would give less reliable dose estimates and therefore complete translocations are preferred.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9687972     DOI: 10.1080/095530098141690

Source DB:  PubMed          Journal:  Int J Radiat Biol        ISSN: 0955-3002            Impact factor:   2.694


  4 in total

Review 1.  First steps towards systems radiation biology studies concerned with DNA and chromosome structure within living cells.

Authors:  Werner Friedland; Herwig G Paretzke; Francesca Ballarini; Andrea Ottolenghi; Gregor Kreth; Christoph Cremer
Journal:  Radiat Environ Biophys       Date:  2008-01-10       Impact factor: 1.925

2.  Calibration curves by 60Co with low dose rate are different in terms of dose estimation - a comparative study.

Authors:  Mariana Esposito Mendes; Julyanne Conceição Goes de Mendonça; Suy Hwang; Marina Di Giorgio; Fabiana Farias de Lima; Neide Santos
Journal:  Genet Mol Biol       Date:  2020-02-17       Impact factor: 1.771

3.  New sequence-based data on the relative DNA contents of chromosomes in the normal male and female human diploid genomes for radiation molecular cytogenetics.

Authors:  Mikhail V Repin; Pavel I Golubev; Ludmila A Repina
Journal:  Mol Cytogenet       Date:  2009-06-05       Impact factor: 2.009

4.  A dose-response curve for biodosimetry from a 6 MV electron linear accelerator.

Authors:  M M P Lemos-Pinto; M Cadena; N Santos; T S Fernandes; E Borges; A Amaral
Journal:  Braz J Med Biol Res       Date:  2015-05-26       Impact factor: 2.590

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.