Protein-membrane interactions during hemodialysis: effects on solute transport.

S M Morti1, A L Zydney.   

Abstract

Although several previous studies have shown that plasma protein adsorption can reduce solute clearance during hemodialysis, there is currently no quantitative understanding of the factors that govern the extent of these protein-membrane interactions. In this study, quantitative data were obtained for the clearance of urea, vitamin B12, and polydisperse dextrans using polyacrylonitrile (AN69) and cellulose triacetate dialyzers before and after exposure to human plasma in a simulated dialysis session. Contact with plasma had little effect on clearance of urea and vitamin B12, but caused more than an order of magnitude reduction in clearance for solutes with molecular weights > 10,000. These data were analyzed using a two layer model in which contact with plasma was assumed to cause a thin protein layer to form on the surface of the membrane. The protein layer had an effective pore size of approximately 12 A, and was approximately 1 microm thick, as determined by a hydrodynamic analysis of the clearance data, and from independent estimates based on changes in fiber bundle volume and ultrafiltration coefficient. The thickness of the protein layer increased with increasing dialysis time, ranging from 0.25 microm after 40 min to 0.86 microm after 180 min. These results provide important insights into the effects of contact with plasma on solute clearance during hemodialysis.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9682960     DOI: 10.1097/00002480-199807000-00015

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  6 in total

1.  Outside-In Hemofiltration for Prolonged Operation without Clogging.

Authors:  Stanislav S Dukhin; Yacoob Tabani; Richard Lai; Omar A Labib; Andrew L Zydney; Mohamed E Labib
Journal:  J Memb Sci       Date:  2014-08-15       Impact factor: 8.742

2.  Solute clearance in CRRT: prescribed dose versus actual delivered dose.

Authors:  William D Lyndon; Keith M Wille; Ashita J Tolwani
Journal:  Nephrol Dial Transplant       Date:  2011-09-05       Impact factor: 5.992

3.  An experimental and numerical study of the flow and mass transfer in a model of the wearable artificial kidney dialyzer.

Authors:  Edmond Rambod; Masoud Beizai; Moshe Rosenfeld
Journal:  Biomed Eng Online       Date:  2010-05-24       Impact factor: 2.819

4.  Computational assessment of the effects of a pulsatile pump on toxin removal in blood purification.

Authors:  Ki Moo Lim; Eun Bo Shim
Journal:  Biomed Eng Online       Date:  2010-06-22       Impact factor: 2.819

5.  Effect of Membrane Surface Area on Solute Removal Performance of Dialyzers with Fouling.

Authors:  Takayoshi Kiguchi; Hiromi Ito; Akihiro C Yamashita
Journal:  Membranes (Basel)       Date:  2022-07-01

6.  Enhancement of solute clearance using pulsatile push-pull dialysate flow for the Quanta SC+: A novel clinic-to-home haemodialysis system.

Authors:  Clive Buckberry; Nicholas Hoenich; Detlef Krieter; Horst-Dieter Lemke; Marieke Rüth; John E Milad
Journal:  PLoS One       Date:  2020-03-02       Impact factor: 3.240