The influence of strain rate on the passive and stimulated engineering stress--large strain behavior of the rabbit tibialis anterior muscle.

B S Myers1, C T Woolley, T L Slotter, W E Garrett, T M Best.   

Abstract

The passive and stimulated engineering stress-large strain mechanical properties of skeletal muscle were measured at the midbelly of the rabbit tibialis anterior. The purpose of these experiments was to provide previously unavailable constitutive information based on the true geometry of the muscle and to determine the effect of strain rate on these responses. An apparatus including an ultrasound imager, high-speed digital imager, and a servohydraulic linear actuator was used to apply constant velocity deformations to the tibialis anterior of an anesthetized neurovascularly intact rabbit. The average isometric tetanic stress prior to elongation was 0.44 +/- 0.15 MPa. During elongation the average stimulated modulus was 0.97 +/- 0.34 MPa and was insensitive to rate of loading. The passive stress-strain responses showed a nonlinear stiffening response typical of biologic soft tissue. Both the passive and stimulated stress-strain responses were sensitive to strain rate over the range of strain rates (1 to 25 s-1). Smaller changes in average strain rate (1 to 10, and 10 to 25 s-1) did not produce statistically significant changes in these responses, particularly in the stimulated responses, which were less sensitive to average strain rate than the passive responses. This relative insensitivity to strain rate suggests that pseudoelastic functions generated from an appropriate strain rate test may be suitable for the characterization of the responses of muscle over a narrow range of strain rates, particularly in stimulated muscle.

Entities:  

Mesh:

Year:  1998        PMID: 9675691     DOI: 10.1115/1.2834292

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  7 in total

1.  An anatomical investigation of the human cervical facet capsule, quantifying muscle insertion area.

Authors:  B A Winkelstein; R E McLendon; A Barbir; B S Myers
Journal:  J Anat       Date:  2001-04       Impact factor: 2.610

Review 2.  Engineering complex orthopaedic tissues via strategic biomimicry.

Authors:  Dovina Qu; Christopher Z Mosher; Margaret K Boushell; Helen H Lu
Journal:  Ann Biomed Eng       Date:  2014-12-03       Impact factor: 3.934

3.  Skeletal muscle tensile strain dependence: Hyperviscoelastic nonlinearity.

Authors:  Benjamin B Wheatley; Duane A Morrow; Gregory M Odegard; Kenton R Kaufman; Tammy L Haut Donahue
Journal:  J Mech Behav Biomed Mater       Date:  2015-09-08

Review 4.  Cellular mechanisms of tissue fibrosis. 4. Structural and functional consequences of skeletal muscle fibrosis.

Authors:  Richard L Lieber; Samuel R Ward
Journal:  Am J Physiol Cell Physiol       Date:  2013-06-12       Impact factor: 4.249

5.  Diabetic Conditions Confer Metabolic and Structural Modifications to Tissue-Engineered Skeletal Muscle.

Authors:  Francisca M Acosta; U-Ter Aonda Jia; Katerina Stojkova; Kennedy K Howland; Teja Guda; Settimio Pacelli; Eric M Brey; Christopher R Rathbone
Journal:  Tissue Eng Part A       Date:  2020-10-06       Impact factor: 3.845

6.  Adipogenic Differentiation Alters Properties of Vascularized Tissue-Engineered Skeletal Muscle.

Authors:  Francisca M Acosta; Kennedy K Howland; Katerina Stojkova; Elizabeth Hernandez; Eric M Brey; Christopher R Rathbone
Journal:  Tissue Eng Part A       Date:  2021-08-25       Impact factor: 3.845

7.  Are cervical multifidus muscles active during whiplash and startle? An initial experimental study.

Authors:  Gunter P Siegmund; Jean-Sébastien Blouin; Mark G Carpenter; John R Brault; J Timothy Inglis
Journal:  BMC Musculoskelet Disord       Date:  2008-06-05       Impact factor: 2.362

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.