Literature DB >> 9672983

Simultaneous and correlated detection of endocardial and epicardial borders on short-axis MR images for the measurement of left ventricular mass.

P Balzer1, A Furber, C Cavaro-Ménard, A Croué, A Tadéi, P Geslin, P Jallet, J J Le Jeune.   

Abstract

A method was developed for fast, reproducible assessment of left ventricular mass with detection of the endocardial and epicardial borders. The method makes use of short-axis magnetic resonance (MR) imaging in conjunction with an integrated segmentation approach that includes region growing, edge detection, and adaptive thresholding. The mass of the left ventricle in nine Yucatan minipigs was measured ex vivo and compared with the mass as determined in vivo with both full automated segmentation and an interactive process involving two trained observers. The test sample consisted of 59 sections obtained during diastole. There was good correlation between actual mass and both automatically and manually assessed mass. Linear regression analysis showed that the difference between ex vivo measurement and automatic mass assessment (standard error of estimation [SEE] = 5 g) was similar to interobserver variability in interactive mass assessment (SEE = 4 g). Mass assessment with short-axis MR imaging and an integrated segmentation approach does not require location of the ventricular cavity and allows precise delineation of the endocardial and epicardial borders. The results of this experimental study are encouraging for the potential use of this technique in clinical cardiac functional analyses.

Mesh:

Year:  1998        PMID: 9672983     DOI: 10.1148/radiographics.18.4.9672983

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  4 in total

1.  Comparative evaluation of active contour model extensions for automated cardiac MR image segmentation by regional error assessment.

Authors:  Duy Nguyen; Karen Masterson; Jean-Paul Vallée
Journal:  MAGMA       Date:  2007-03-06       Impact factor: 2.310

2.  Clinical validation of an automated boundary tracking algorithm on cardiac MR images.

Authors:  L A Latson; K A Powell; B Sturm; P R Schvartzman; R D White
Journal:  Int J Cardiovasc Imaging       Date:  2001-08       Impact factor: 2.357

3.  Development and clinical validation of a hybrid method for semiautomated left ventricle endocardial and epicardial boundary extraction on cine-magnetic resonance images.

Authors:  Mahammed Messadi; Abdelhafid Bessaid; Denis Mariano-Goulart; Fayçal Ben Bouallègue
Journal:  J Med Imaging (Bellingham)       Date:  2018-04-11

4.  Agreement of left ventricular mass in steady state free precession and delayed enhancement MR images: implications for quantification of fibrosis in congenital and ischemic heart disease.

Authors:  Sigurdur S Stephensen; Marcus Carlsson; Martin Ugander; Henrik Engblom; Goran Olivecrona; David Erlinge; Hakan Arheden
Journal:  BMC Med Imaging       Date:  2010-01-24       Impact factor: 1.930

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.