Literature DB >> 9671898

Coronary artery bypass grafting without cardiopulmonary bypass using the octopus method: results in the first one hundred patients.

E W Jansen1, C Borst, J R Lahpor, P F Gründeman, F D Eefting, A Nierich, E O Robles de Medina, J J Bredée.   

Abstract

OBJECTIVE: Cardiopulmonary bypass and global cardiac arrest enable safe coronary artery bypass grafting but have adverse effects. In off-pump coronary bypass grafting, invasiveness is reduced, but anastomosis suturing is jeopardized by cardiac motion. Therefore the key to successful off-pump coronary bypass grafting is effective local cardiac wall stabilization.
METHODS: We prospectively assessed the safety and efficacy of the Octopus tissue stabilizer (Medtronic, Inc., Minneapolis, Minn.) in the first 100 patients selected for off-pump coronary bypass via full or limited surgical access. To immobilize and expose the coronary artery, two suction paddles (-400 mm Hg), fixed to the operating table-rail by an articulating arm, stabilized the anastomosis site.
RESULTS: One hundred forty-one grafts (96% arterial) were used to create 172 anastomoses (17% side-to-side), up to 4 per patient, on average 23 in the full access group (46 patients) and 1.2 in the limited access group (54 patients). Complications included conversion to cardiopulmonary bypass (2%), conversion from limited to full access (3%), myocardial infarction (4%), predischarge coronary reintervention (2%), and late coronary reintervention (1%). Median postoperative length of hospital stay was 4 days (limited access) or 5 days (full access). Rapid recovery allowed 96% of patients to resume social activities within 1 month. At the 6-month angiographic follow-up, 95% of anastomoses was patent. At the 2- to 22-month follow-up (mean, 13 months), 98 patients were in Canadian Cardiovascular Society class I and 2 patients were in class II.
CONCLUSION: These results suggest that off-pump coronary artery bypass grafting with the Octopus tissue stabilizer is safe. Early clinical outcome and patency rates warrant a randomized study comparing this methods with conventional coronary bypass grafting.

Entities:  

Mesh:

Year:  1998        PMID: 9671898     DOI: 10.1016/S0022-5223(98)70243-0

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  21 in total

1.  Off-pump coronary artery bypass grafting via partial sternotomy. An alternative to left anterior small thoracotomy.

Authors:  M Takeda; T Konishi; M Fukata; K Matsuzaki; K Furuya
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2000-01

2.  Coronary artery bypass grafting in dialysis patients.

Authors:  H Tanaka; K Suzuki; T Narisawa; T Ookura; Y Kamio; S Suzuki; A Kitami; T Suzuki; T Takaba
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2000-11

Review 3.  Left internal mammary artery grafting to left anterior descending coronary artery by minimally invasive direct coronary artery bypass approach.

Authors:  A Diegeler
Journal:  Curr Cardiol Rep       Date:  1999-11       Impact factor: 2.931

Review 4.  Multivessel coronary bypass grafting without cardiopulmonary support.

Authors:  T M Dewey; M J Mack
Journal:  Curr Cardiol Rep       Date:  1999-11       Impact factor: 2.931

5.  Combined coronary artery and abdominal aortic surgery without cardiopulmonary bypass.

Authors:  R Ascione; G Iannelli; N Spampinato
Journal:  Tex Heart Inst J       Date:  2000

Review 6.  The role of myocardial ischaemic preconditioning during beating heart surgery: biological aspect and clinical outcome.

Authors:  Efstratios Apostolakis; Nikolaos G Baikoussis; Nikolaos A Papakonstantinou
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-11-15

Review 7.  High-frequency epicardial ultrasound: review of a multipurpose intraoperative tool for coronary surgery.

Authors:  Ricardo P J Budde; Patricia F A Bakker; Paul F Gründeman; Cornelius Borst
Journal:  Surg Endosc       Date:  2008-09-20       Impact factor: 4.584

Review 8.  Off-pump coronary artery bypass graft surgery: the incidence of postoperative atrial fibrillation.

Authors:  R A Archbold; N P Curzen
Journal:  Heart       Date:  2003-10       Impact factor: 5.994

9.  Local cardiac wall stabilization influences the reproducibility of regional wall motion during off-pump coronary artery pass surgery.

Authors:  T Shiga; K Terajima; J Matsumura; A Sakamoto; R Ogawa
Journal:  J Clin Monit Comput       Date:  2000-01       Impact factor: 2.502

10.  The effect of milrinone infusion on right ventricular function during coronary anastomosis and early outcomes in patients undergoing off-pump coronary artery bypass surgery.

Authors:  Hyong Rae Jo; Woo Kyung Lee; Yong Ho Kim; Jin Hye Min; Young Keun Chae; In Gyu Choi; Young Sin Kim; Yong Kyung Lee
Journal:  Korean J Anesthesiol       Date:  2010-08-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.