Literature DB >> 9671172

Comparison of an inhalant allergy immunoassay with allergen specific IgE determinations in human serum.

T B Martins1, C M Litwin, T D Jaskowski, H R Hill.   

Abstract

The diagnosis of inhalant allergy can be elusive, with symptoms resembling viral or bacterial infection, as well as immunologic deficiency. In this study an inhalant allergy immunoassay was investigated as a possible screen to rule in or out respiratory inhalant allergy in patients with allergic-type symptoms. The results of this screen were compared in 192 serum specimens submitted to our laboratory for specific IgE allergy testing and 73 blood bank samples. When the discrepant results of the inhalant allergy immunoassay were resolved by Western blot, a final sensitivity of 94.7% and specificity of 97.5% was calculated. We have found this inhalant allergy immunoassay to be an effective screen for detecting inhalant allergies, and believe it to be a useful tool for the primary care physician or non-allergist trying to differentiate inhalant allergens from chronic sinusitis or other causes of sinopulmonary congestion.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9671172      PMCID: PMC6807895          DOI: 10.1002/(sici)1098-2825(1998)12:4<213::aid-jcla4>3.0.co;2-8

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  11 in total

1.  Clinical evaluation of CAP System and RAST in the measurement of specific IgE.

Authors:  E A Pastorello; C Incorvaia; V Pravettoni; A Marelli; L Farioli; M Ghezzi
Journal:  Allergy       Date:  1992-10       Impact factor: 13.146

2.  Comparative evaluation of the pharmacia CAP system and the DPC AlaSTAT system for in vitro detection of allergen-specific IgE with the skin prick test.

Authors:  A J van Houte; P C Bartels
Journal:  Eur J Clin Chem Clin Biochem       Date:  1992-02

3.  Serum IgE levels in healthy children quantified by a sandwich technique (PRIST).

Authors:  N M Kjellman; S G Johansson; A Roth
Journal:  Clin Allergy       Date:  1976-01

4.  The IMMULITE assay tube: a new approach to heterogeneous ligand assay.

Authors:  A L Babson; D R Olson; T Palmieri; A F Ross; D M Becker; P J Mulqueen
Journal:  Clin Chem       Date:  1991-09       Impact factor: 8.327

5.  Evaluation of a capsulated hydrophilic carrier polymer (the ImmunoCAP) for measurement of specific IgE antibodies.

Authors:  P W Ewan; D Coote
Journal:  Allergy       Date:  1990-01       Impact factor: 13.146

6.  Diagnostic performance characteristics of the standard Phadebas RAST, modified RAST, and pharmacia CAP system versus skin testing.

Authors:  J M Kelso; N Sodhi; V A Gosselin; J W Yunginger
Journal:  Ann Allergy       Date:  1991-11

7.  Human IgE.

Authors:  R S Geha
Journal:  J Allergy Clin Immunol       Date:  1984-08       Impact factor: 10.793

8.  Distribution of IgE in a community population sample: correlations with age, sex, and allergen skin test reactivity.

Authors:  R A Barbee; M Halonen; M Lebowitz; B Burrows
Journal:  J Allergy Clin Immunol       Date:  1981-08       Impact factor: 10.793

9.  Comparison between MAGIC LITE- and CAP-system: two automated specific IgE antibody assays.

Authors:  J Kleine-Tebbe; M Eickholt; M Gätjen; T Brunnée; A O'Connor; G Kunkel
Journal:  Clin Exp Allergy       Date:  1992-04       Impact factor: 5.018

10.  Clinical efficiency of in vitro and in vivo tests for allergic diseases.

Authors:  M Plebani; F Borghesan; D Faggian
Journal:  Ann Allergy Asthma Immunol       Date:  1995-01       Impact factor: 6.347

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.