Literature DB >> 9669447

Computer aided monitor-data processing (CAMP). A landmark for unbiased gauging of anaesthetic courses?

A Petry1.   

Abstract

UNLABELLED: A computer aided monitor-data processing system (CAMP-System) was developed in order to get a consistent and comprehensive database which can very precisely reflect intra-operative haemodynamic courses. The goal of the present study was to introduce a new method to scan and to gauge haemodynamic courses and to demonstrate its superiority over the traditional way of data processing based on a handwritten anaesthesia protocol.
METHODS: The computerized system was applied to a study which was designed to investigate the influence of ketanserin (K) vs. urapidil (U) on haemodynamic stability during cardiac operations. Twenty male patients scheduled for myocardial revascularization received either 20 mg K or 30 mg U. Heart rate, central venous, arterial and pulmonary artery pressures were measured and on-line recorded every 20 seconds by the computer record system. In the handwritten protocol these variables were registered at eight pre-defined time points. Computerized data processing (including artifact depletion and data condensation) was compared to the results evaluated from the handwritten protocol.
RESULTS: While the only significant differences in the handwritten protocol were slightly higher values of pulmonary artery pressures in group K, the computer analysis revealed a number of further differences. Higher maximum and a less stable time course of HR in group K in the pre-bypass phase and lower mean and standard deviation of MAP during cardiopulmonary bypass.
CONCLUSION: Computerized data processing including automatic artifact suppression and data condensation was able to reveal differences in the course of haemodynamic variables that cannot be detected in a conventional handwritten protocol.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9669447     DOI: 10.1023/a:1007412615313

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  20 in total

1.  Eight year's experience with automated anesthesia record keeping: lessons learned--new directions taken.

Authors:  J P Abenstein; C B De Vos; M D Abel; S Tarhan
Journal:  Int J Clin Monit Comput       Date:  1992

2.  Artifacts.

Authors:  J S Gage
Journal:  MD Comput       Date:  1992 Sep-Oct

3.  Detection of intraoperative incidents by electronic scanning of computerized anesthesia records. Comparison with voluntary reporting.

Authors:  K V Sanborn; J Castro; M Kuroda; D M Thys
Journal:  Anesthesiology       Date:  1996-11       Impact factor: 7.892

4.  Differences between handwritten and automatic blood pressure records.

Authors:  R I Cook; J S McDonald; E Nunziata
Journal:  Anesthesiology       Date:  1989-09       Impact factor: 7.892

5.  [Computer-aided anesthesia monitoring. Experiences with the use of three systems in heart surgery].

Authors:  A Petry; H Gockel; H Wulf
Journal:  Anaesthesist       Date:  1993-08       Impact factor: 1.041

6.  Comparison of the hemodynamic effects of urapidil and flesinoxan in healthy volunteers.

Authors:  P A Van Zwieten; T A Bruning
Journal:  Blood Press Suppl       Date:  1994

7.  [Computerized recording of physiologic parameters monitored during anesthesia].

Authors:  P Gregorini; G Manico; P Depatre
Journal:  Minerva Anestesiol       Date:  1993-10       Impact factor: 3.051

8.  Computerized patient anesthesia records: less time and better quality than manually produced anesthesia records.

Authors:  D W Edsall; P Deshane; C Giles; D Dick; B Sloan; J Farrow
Journal:  J Clin Anesth       Date:  1993 Jul-Aug       Impact factor: 9.452

9.  Does chronic treatment with calcium entry blocking drugs reduce perioperative myocardial ischemia?

Authors:  S Slogoff; A S Keats
Journal:  Anesthesiology       Date:  1988-05       Impact factor: 7.892

10.  Ketanserin and the cardiovascular system. 2. A study of its effects in patients undergoing myocardial revascularisation.

Authors:  H B Griffiths; J G Whitwam
Journal:  Anaesthesia       Date:  1986-07       Impact factor: 6.955