Literature DB >> 9659596

Direct magnification technique for cerebral angiography in the rat.

W Luedemann1, T Brinker, M U Schuhmann, A I von Brenndorf, M Samii.   

Abstract

RATIONALE AND
OBJECTIVES: The authors evaluated the performance of direct magnification radiography (DIMA) with digital image processing for cerebral angiography in the rat.
METHODS: A microfocal x-ray unit with a focal spot of 5 microns was used for cerebral angiography in 10 rats. The animals were examined form x 4 up to x 20 magnification after injection of 0.2 mL x-ray contrast medium into the common carotid artery.
RESULTS: Direct magnification radiography technology provides high resolution images and enables the visualization of very small vessels with high quality. It allows the peripheral branches of the middle cerebral artery or the ophthalmic artery to be visualized. Superimposition and noise effects can be excluded with digital subtraction and image processing.
CONCLUSIONS: The experiments show that DIMA radiography is a suitable technique for cerebral angiography in the rat.

Entities:  

Mesh:

Year:  1998        PMID: 9659596     DOI: 10.1097/00004424-199807000-00008

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

1.  New angiographic measurement tool for analysis of small cerebral vessels: application to a subarachnoid haemorrhage model in the rat.

Authors:  B Turowski; D Hänggi; A Beck; V Aurich; H J Steiger; U Moedder
Journal:  Neuroradiology       Date:  2006-11-17       Impact factor: 2.804

2.  A high-precision contrast injector for small animal x-ray digital subtraction angiography.

Authors:  Ming de Lin; Lutao Ning; Cristian T Badea; Nilesh N Mistry; Yi Qi; G Allan Johnson
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

3.  Characterization of Continuous and Pulsed Emission modes of a Hybrid Micro Focus X-ray Source for Medical Imaging Applications.

Authors:  Muhammad U Ghani; Molly D Wong; Liqiang Ren; Di Wu; Bin Zheng; John X Rong; Xizeng Wu; Hong Liu
Journal:  Nucl Instrum Methods Phys Res A       Date:  2017-02-16       Impact factor: 1.455

4.  Assessment of vasospasm in experimental subarachnoid hemorrhage in rats by selective biplane digital subtraction angiography.

Authors:  Stefan Weidauer; Hartmut Vatter; Edgar Dettmann; Volker Seifert; Friedhelm E Zanella
Journal:  Neuroradiology       Date:  2006-02-02       Impact factor: 2.804

  4 in total