Literature DB >> 9659482

Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail.

S Kawaguchi1, K Sawada, Y Nabeta.   

Abstract

Sixty consecutive intertrochanteric femoral fractures were treated with the Asiatic gamma nail followed by early postoperative weight bearing. Cutting-out of the lag screw from the femoral head occurred in six fractures and were analysed radiographically with regard to fracture type (Evans' classification), osteoporosis (Singh grade), accuracy of post-operative reduction (neck-shaft angle and diastasis of the fracture), and location of the lag screw in the femoral head (depth, height, and antero-postero-posterior radiograph and large antero-posterior deviation of the lag screw were significantly related to the increased incidence of the screw cutting-out. This suggests that deep insertion of the lag screw on the antero-posterior view with central placement on the lateral view is an optimal location in the femoral head. The ¿cut-out index' (the multiplication value of the depth and the anteroposterior deviation of the lag screw in the femoral head) is an excellent measure of the risk of the lag screw cutting-out.

Entities:  

Mesh:

Year:  1998        PMID: 9659482     DOI: 10.1016/s0020-1383(97)00158-7

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  13 in total

1.  Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur.

Authors:  A J Shyam Kumar; V Parmar; J Bankart; S C Williams; W M Harper
Journal:  Int Orthop       Date:  2006-05-06       Impact factor: 3.075

2.  [Treatment of intracapsular fractures of the femoral neck with a biaxial proximal femoral nail].

Authors:  P Visna; E Beitl; R Hart; I Cizmar; J Pilny; Z Smidl
Journal:  Unfallchirurg       Date:  2008-05       Impact factor: 1.000

3.  How to prevent cut-out and cut-through in biaxial proximal femoral nails: is there anything beyond lag screw positioning and tip-apex distance?

Authors:  Birgit Zirngibl; Roland Biber; Hermann Josef Bail
Journal:  Int Orthop       Date:  2013-05-07       Impact factor: 3.075

4.  Early Complications in Proximal Femoral Nailing Done for Treatment of Subtrochanteric Fractures

Authors:  B Kanthimathi; Vl Narayanan
Journal:  Malays Orthop J       Date:  2012-03

5.  Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS).

Authors:  Kyu Yeol Lee; Sung Soo Kim; Hyeon Jun Kim; Dong Ho Ha; Hyung Min Yoon; Hyun Su Do
Journal:  Hip Pelvis       Date:  2015-03-31

Review 6.  Treatment strategies for proximal femur fractures in osteoporotic patients.

Authors:  Felix Bonnaire; Henry Zenker; Christoph Lill; Andreas T Weber; Berend Linke
Journal:  Osteoporos Int       Date:  2004-10-16       Impact factor: 4.507

Review 7.  Influence of osteoporosis on fracture fixation--a systematic literature review.

Authors:  J Goldhahn; N Suhm; S Goldhahn; M Blauth; B Hanson
Journal:  Osteoporos Int       Date:  2008-06       Impact factor: 4.507

8.  How evolution of the nailing system improves results and reduces orthopedic complications: more than 2000 cases of trochanteric fractures treated with the Gamma Nail System.

Authors:  R Pascarella; R Fantasia; A Maresca; C Bettuzzi; L Amendola; S Violini; F Cuoghi; P Sangiovanni; S Cerbasi; S Boriani; D S Tigani
Journal:  Musculoskelet Surg       Date:  2015-12-14

9.  Critical factors in cut-out complication after Gamma Nail treatment of proximal femoral fractures.

Authors:  Alicja J Bojan; Claudia Beimel; Gilbert Taglang; David Collin; Carl Ekholm; Anders Jönsson
Journal:  BMC Musculoskelet Disord       Date:  2013-01-02       Impact factor: 2.362

10.  Improved lag screw positioning in the treatment of proximal femur fractures using a novel computer assisted surgery method: a cadaveric study.

Authors:  Matthias Regling; Arno Blau; Robert A Probe; James W Maxey; Brian D Solberg
Journal:  BMC Musculoskelet Disord       Date:  2014-05-30       Impact factor: 2.362

View more