Literature DB >> 9657579

References values for forced spirometry. Group of the European Community Respiratory Health Survey.

J Roca1, F Burgos, J Sunyer, M Saez, S Chinn, J M Antó, R Rodríguez-Roisin, P H Quanjer, D Nowak, P Burney.   

Abstract

The European Coal and Steel Community (ECSC) prediction equations exemplify a significant effort carried out approximately 15 yrs ago to provide uniform standards for lung function testing, but this set of equations has not been properly validated as yet. The present study evaluates the ECSC reference values and four other sets of prediction equations, using spirometric data collected in 12,900 nonasthmatic subjects (43% lifetime nonsmokers and 36% active smokers) aged 20-44 yrs from the European Community Respiratory Health Survey (ECRHS). Standardized spirometric measurements were obtained using a common protocol in 34 centres in 14 countries. For each prediction equation, the prediction deviations (i.e. observed minus predicted value) for forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) were examined for the whole study population and for each centre. For the age range included, the errors about the ECSC equations showed the most prominent underestimation of both predicted FVC (+355 and +360 mL on average in males and females, respectively) and predicted FEV1 (+211 and +200 mL, respectively) among the five studies examined. As expected, FVC and FEV1 in active smokers from the ECRHS were significantly lower than in lifetime nonsmokers (each p<0.01). We conclude that the present European recommendations on lung function reference values should be reconsidered, but further data for nonsymptomatic subjects above the age of 44 yrs are needed.

Mesh:

Year:  1998        PMID: 9657579     DOI: 10.1183/09031936.98.11061354

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  57 in total

1.  Respiratory health effects from exposure to carbon black: results of the phase 2 and 3 cross sectional studies in the European carbon black manufacturing industry.

Authors:  K Gardiner; M van Tongeren; M Harrington
Journal:  Occup Environ Med       Date:  2001-08       Impact factor: 4.402

2.  Accuracy and precision of perfusion lung scintigraphy versus 133Xe-radiospirometry for preoperative pulmonary functional assessment of patients with lung cancer.

Authors:  Denis Mariano-Goulart; Eric Barbotte; Célia Basurko; F Comte; Michel Rossi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-26       Impact factor: 9.236

3.  Application of a new spirometric reference equation and its impact on the staging of Korean chronic obstructive pulmonary disease patients.

Authors:  Yong Il Hwang; Eun Ji Kim; Chang Youl Lee; Sunghoon Park; Jeong Hee Choi; Yong Bum Park; Seung Hun Jang; Cheol Hong Kim; Tae Rim Shin; Sang Myeon Park; Dong-Gyu Kim; Myung-Goo Lee; In-Gyu Hyun; Ki-Suck Jung
Journal:  Yonsei Med J       Date:  2012-03       Impact factor: 2.759

Review 4.  Asthma exacerbations. 5: assessment and management of severe asthma in adults in hospital.

Authors:  Sarah Aldington; Richard Beasley
Journal:  Thorax       Date:  2007-05       Impact factor: 9.139

5.  Nonparametric spirometry reference values for Hispanic Americans.

Authors:  Nancy L Glenn; Vanessa M Brown
Journal:  J Immigr Minor Health       Date:  2011-02

6.  Can new pulmonary gas exchange parameters contribute to evaluation of pulmonary congestion in left-sided heart failure?

Authors:  J Moesgaard; J Hedegaard Kristensen; J Malczynski; C Holst-Hansen; S Edward Rees; D Murley; S Andreassen; J Brondum Frokjaer; E Toft
Journal:  Can J Cardiol       Date:  2009-03       Impact factor: 5.223

7.  Phenotypes of COPD in an Austrian population : National data from the POPE study.

Authors:  Gabriele Reiger; Ralf Zwick; Bernd Lamprecht; Christian Kähler; Otto Chris Burghuber; Arschang Valipour
Journal:  Wien Klin Wochenschr       Date:  2018-05-24       Impact factor: 1.704

8.  Asthma, chronic bronchitis, and exposure to irritant agents in occupational domestic cleaning: a nested case-control study.

Authors:  M Medina-Ramón; J P Zock; M Kogevinas; J Sunyer; Y Torralba; A Borrell; F Burgos; J M Antó
Journal:  Occup Environ Med       Date:  2005-09       Impact factor: 4.402

9.  Plasma vitamin C concentrations and risk of incident respiratory diseases and mortality in the European Prospective Investigation into Cancer-Norfolk population-based cohort study.

Authors:  Phyo Kyaw Myint; Andrew M Wilson; Allan B Clark; Robert N Luben; Nicholas J Wareham; Kay-Tee Khaw
Journal:  Eur J Clin Nutr       Date:  2019-01-31       Impact factor: 4.016

10.  The prognostic significance of lung function in stable heart failure outpatients.

Authors:  Louis Lind Plesner; Morten Dalsgaard; Morten Schou; Lars Køber; Jørgen Vestbo; Erik Kjøller; Kasper Iversen
Journal:  Clin Cardiol       Date:  2017-09-13       Impact factor: 2.882

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.