Literature DB >> 9656175

In vitro study of the number of surface defects in monophase and two-phase addition silicone impressions.

B J Millar1, S M Dunne, P B Robinson.   

Abstract

STATEMENT OF PROBLEM: Monophase addition-cured silicone impression materials in stock trays are considered to be alternatives to two-phase systems used with custom trays.
PURPOSE: This study compared the number of surface defects in addition-cured silicone impressions recorded with monophase materials in stock trays and two-phase impressions in custom trays.
METHODS: The number of voids visible on the surface of impressions recorded in vitro were counted. Two monophase impression materials. (President Monobody system 75, Bayer Cutter) in stock trays were compared with impressions recorded with two-phase addition silicone materials (President Plus light-body/regular-body and Zhermack Elite light-body/medium-body) in custom trays. A total of 200 automixed impressions, 50 with each material, were recorded of 50 dentoform molar teeth prepared for full veneer crowns. Impressions were examined for surface voids anywhere on the prepared part of the tooth by a trained examiner.
RESULTS: Mean number of voids observed for the monophase impressions were 3.0 +/- 2.2 for President Monobody system and 3.4 +/- 2.0 for Bayer Cutter system. Mean number of voids for the two-phase materials were 0.8 +/- 1.0 for President Plus, and 1.0 +/- 1.1 for Zhermack Elite. No significant differences were observed for number of voids between the monophase materials or between the two-phase systems (ANOVA and Neuman-Keuls p > 0.05). However, both two-phase materials in custom trays had significantly fewer surface voids than the two-monophase materials (ANOVA and Neuman-Keuls, p < 0.001) used in stock trays.
CONCLUSION: Monophase addition-cured impression materials in stock trays carries an increased risk of void formation on the surface of the impression when compared with two-phase addition silicone materials in custom trays.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9656175     DOI: 10.1016/s0022-3913(98)70088-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

1.  A Comparison of Dimensional Accuracy of Addition Silicone of Different Consistencies with Two Different Spacer Designs - In-vitro Study.

Authors:  Suprabha Rathee; B Eswaran; Ma Eswaran; R Prabhu; Kr Geetha; Gp Krishna
Journal:  J Clin Diagn Res       Date:  2014-07-20

2.  Effect of pouring time and storage temperature on dimensional stability of casts made from irreversible hydrocolloid.

Authors:  M Farzin; H Panahandeh
Journal:  J Dent (Tehran)       Date:  2010-09-30

3.  Evaluation of surface detail reproduction, dimensional stability and gypsum compatibility of monophase polyvinyl-siloxane and polyether elastomeric impression materials under dry and moist conditions.

Authors:  Sriharsha Babu Vadapalli; Kaleswararao Atluri; Madhu Sudhan Putcha; Sirisha Kondreddi; N Suman Kumar; Durga Prasad Tadi
Journal:  J Int Soc Prev Community Dent       Date:  2016 Jul-Aug

4.  Accuracy of Multiple Pour Cast from Various Elastomer Impression Methods.

Authors:  Satheesh B Haralur; Majed Saad Toman; Abdullah Ali Al-Shahrani; Abdullah Ali Al-Qarni
Journal:  Int J Dent       Date:  2016-12-14

5.  Comparative analysis of different impression techniques in relation to single tooth impression.

Authors:  Aman Merchant; Subhabrata Maiti; V Ashok; Dhanraj M Ganapathy
Journal:  Bioinformation       Date:  2020-12-31

6.  Comparative Evaluation of Wettability at Various Stages of Working Time for Light Body and Medium Body Consistencies of Three Elastomeric Impression Materials.

Authors:  Ashwini Obla Rameshbabu; Divagar Chandrasekaran; Saravanakumar Mariappan; Sethuraman Ramadoss; Arjun Badimela; Aishwarya Krishnaswamy
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

7.  Accuracy of different putty-wash impression techniques with various spacer thickness.

Authors:  Anshul Chugh; Aman Arora; Vijay Pratap Singh
Journal:  Int J Clin Pediatr Dent       Date:  2012-02-24

8.  A Comparative Evaluation of Marginal Accuracy of Co-Cr Metal Copings Fabricated Using Traditional Casting Techniques and Metal Laser Sintering.

Authors:  Nitin Gautam; Rajat R Khajuria; Rimsha Ahmed; Sunny Sharma; Sarah Hasan; Saad Hasan
Journal:  Int J Clin Pediatr Dent       Date:  2021 Jan-Feb
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.