Literature DB >> 9645721

In vivo quantitative measurement of posterior capsule opacification after extracapsular cataract surgery.

K Hayashi1, H Hayashi, F Nakao, F Hayashi.   

Abstract

PURPOSE: To introduce a new in vivo quantitative measurement of posterior capsule opacification (PCO) after extracapsular cataract surgery and also to analyze the correlation between opacification density and the patient's visual acuity.
METHODS: Prospectively, the opacification density value in the central 3-mm portion of the posterior capsule was quantitated by means of an area densitometry with the Scheimpflug photography system (EAS-1000). The EAS-1000 examination was performed on 40 eyes with clinically significant PCO both before and after undergoing Nd:YAG laser posterior capsulotomy, and on 10 eyes without PCO. The correlation between the opacification density value and the visual acuity was analyzed with a linear regression analysis.
RESULTS: The mean opacification density values +/- SD were 48.8 +/- 29.5 computer-compatible tapes (CCT) steps in the PCO group before capsulotomy, 15.5 +/- 7.8 CCT steps in the PCO group after capsulotomy, and 12.9 +/- 4.9 CCT steps in the non-PCO group. The mean opacification density value in the PCO group before capsulotomy was significantly greater than that in the PCO group after capsulotomy or than that of the non-PCO group. A linear regression analysis determined that the opacification density value also correlated well with the visual acuity (R2 = .808).
CONCLUSIONS: We have established a new in vivo quantitative measurement of PCO. Because the opacification density value obtained by this measurement correlated well with the patient's visual acuity, we consider this measurement to be useful in both the research and clinical management of PCO.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9645721     DOI: 10.1016/s0002-9394(98)00042-7

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  10 in total

1.  Systems of analysis of posterior capsule opacification.

Authors:  T M Aslam; B Dhillon; N Werghi; A Taguri; A Wadood
Journal:  Br J Ophthalmol       Date:  2002-10       Impact factor: 4.638

2.  In vivo measurement of opacified H60M intraocular lenses using Scheimpflug photography.

Authors:  A H Ross; M V Mundasad; S M Neilson; E J Mayer; J M Sparrow; A D Dick; D M Tole
Journal:  Br J Ophthalmol       Date:  2006-10       Impact factor: 4.638

Review 3.  [After-cataract following intraocular lens implantation. Part I. Genesis and prevention by optimizing conventional lens implants and surgical techniques].

Authors:  R Menapace
Journal:  Ophthalmologe       Date:  2007-03       Impact factor: 1.059

4.  [Posterior capsule opacification after phacoemulsification in patients with rheumatoid arthritis].

Authors:  Dusica Pahor; Bojan Gracner; Tomaz Gracner; Artur Pahor
Journal:  Wien Klin Wochenschr       Date:  2006       Impact factor: 1.704

5.  Anterior and posterior capsule densitometry levels after femtosecond laser-assisted cataract surgery.

Authors:  Txomin Alberdi; Javier Mendicute; Lucía Bascarán; Olatz Barandika; Javier Ruiz-Ederra
Journal:  Int J Ophthalmol       Date:  2018-04-18       Impact factor: 1.779

6.  Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.

Authors:  D J Apple
Journal:  Trans Am Ophthalmol Soc       Date:  2000

7.  Posterior capsule morphology determinants of visual function.

Authors:  Tariq Mehmood Aslam; Peter Aspinall; Baljean Dhillon
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-02-20       Impact factor: 3.117

8.  A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses.

Authors:  R Nejima; K Miyata; M Honbou; T Tokunaga; T Tanabe; M Sato; T Oshika
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

9.  Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

Authors:  Xuhua Tan; Haotian Lin; Zhuoling Lin; Jingjing Chen; Xiangchen Tang; Lixia Luo; Weirong Chen; Yizhi Liu
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889

10.  Application of Spectral Domain Optical Coherence Tomography to Objectively Evaluate Posterior Capsular Opacity In Vivo.

Authors:  Shasha Yu; Chengzhe Lu; Xin Tang; Xiaoyong Yuan; Bo Yuan; Zhe Yu
Journal:  J Ophthalmol       Date:  2018-12-23       Impact factor: 1.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.