Literature DB >> 9641420

Posterior chamber phakic intraocular lens for myopia of -8 to -19 diopters.

R Zaldivar1, J M Davidorf, S Oscherow.   

Abstract

PURPOSE: To examine the efficacy, predictability, stability, and safety of posterior chamber phakic intraocular lens (IOL) implantation in patients with extreme myopia.
METHODS: We analyzed the results of 124 eyes that received a posterior chamber hydrogel collagen plate phakic IOL (Staar Collamer Implantable Contact Lens, ICL) for the correction of their myopia. The target postoperative spherical equivalent refraction was emmetropia. Mean follow-up was 11 months (range 1 to 36 mo).
RESULTS: The mean preoperative spherical equivalent refraction was -13.38 +/- 2.23 D (range, -8.50 to -18.63 D). Mean postoperative spherical equivalent refraction at last examination was -0.78 +/- 0.87 D (range, +1.63 to -3.50 D), with 69% (86 eyes) within +/-1.00 D and 44% (55 eyes) within +/-0.50 D of emmetropia. The refraction remained stable with a statistically insignificant change (p > 0.05 at each interval) during follow-up. A gain of two or more lines of spectacle-corrected visual acuity was seen in 36% (45 eyes) at last examination. One eye (0.8%) lost two or more lines of spectacle-corrected visual acuity from a retinal detachment.
CONCLUSION: Posterior chamber phakic IOL implantation with the Staar Collamer plate lens is an effective and safe method for reducing or correcting myopia between -8 and -19 D. Gains in spectacle-corrected visual acuity were common, and results suggested good refractive stability. Improvements in phakic IOL power calculation formulas are needed to improve the predictability of refractive outcome.

Entities:  

Mesh:

Year:  1998        PMID: 9641420     DOI: 10.3928/1081-597X-19980501-13

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  25 in total

1.  Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye.

Authors:  Kunitoshi Fujisawa; Kimiya Shimizu; Shigekazu Uga; Masanobu Suzuki; Koichi Nagano; Yuuki Murakami; Hiroko Goseki
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-04-25       Impact factor: 3.117

2.  Correction of pseudophakic anisometropia in a patient with pseudoexfoliation using an implantable contact lens.

Authors:  N N Ashraff; B V Kumar; A Das; A P Moriarty
Journal:  Br J Ophthalmol       Date:  2004-02       Impact factor: 4.638

Review 3.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 4.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

5.  Posterior chamber phakic intraocular lens implantation for high myopia.

Authors:  Yan Ju; Xiao-Wei Gao; Bing Ren
Journal:  Int J Ophthalmol       Date:  2013-12-18       Impact factor: 1.779

6.  Correction of high myopia with different phakic anterior chamber intraocular lenses: ICARE angle-supported lens and Verisyse iris-claw lens.

Authors:  Stanislawa Gierek-Ciaciura; Ariadna Gierek-Lapinska; Krzysztof Ochalik; Ewa Mrukwa-Kominek
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-07-01       Impact factor: 3.117

Review 7.  [Scheimpflug photography for the examination of phakic intraocular lenses].

Authors:  M Baumeister
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

8.  Pediatric Refractive Surgery: A 2015 Perspective.

Authors:  Erin Durrie Stahl
Journal:  Mo Med       Date:  2015 May-Jun

9.  Repeatability of ocular biometry with IOLMaster 700 in subjects with clear lens.

Authors:  Manuel Garza-Leon; Hugo A Fuentes-de la Fuente; Ana V García-Treviño
Journal:  Int Ophthalmol       Date:  2016-10-21       Impact factor: 2.031

10.  Comparison of clear lens extraction and collamer lens implantation in high myopia.

Authors:  Ahmed M Emarah; Mostafa A El-Helw; Hazem M Yassin
Journal:  Clin Ophthalmol       Date:  2010-05-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.