BACKGROUND: Continuous-loop event recorders are widely used for the evaluation of palpitations, but the optimal duration of monitoring is unknown. OBJECTIVE: To determine the yield, timing, and incremental cost-effectiveness of each week of event monitoring for palpitations. DESIGN: Prospective cohort study. PATIENTS: 105 consecutive outpatients referred for the placement of a continuous-loop event recorder for the evaluation of palpitations. MEASUREMENTS: Diagnostic yield, incremental cost, and cost-effectiveness for each week of monitoring. RESULTS: The diagnostic yield of continuous-loop event recorders was 1.04 diagnoses per patient in week 1, 0.15 diagnoses per patient in week 2, and 0.01 diagnoses per patient in week 3 and beyond. Over time, the cost-effectiveness ratio increased from $98 per new diagnosis in week 1 to $576 per new diagnosis in week 2 and $5832 per new diagnosis in week 3. CONCLUSIONS: In patients referred for evaluation of palpitations, the diagnostic yield of continuous-loop event recording decreases rapidly after 2 weeks of monitoring. A 2-week monitoring period is reasonably cost-effective for most patients and should be the standard period for continuous-loop event recording for the evaluation of palpitations.
BACKGROUND: Continuous-loop event recorders are widely used for the evaluation of palpitations, but the optimal duration of monitoring is unknown. OBJECTIVE: To determine the yield, timing, and incremental cost-effectiveness of each week of event monitoring for palpitations. DESIGN: Prospective cohort study. PATIENTS: 105 consecutive outpatients referred for the placement of a continuous-loop event recorder for the evaluation of palpitations. MEASUREMENTS: Diagnostic yield, incremental cost, and cost-effectiveness for each week of monitoring. RESULTS: The diagnostic yield of continuous-loop event recorders was 1.04 diagnoses per patient in week 1, 0.15 diagnoses per patient in week 2, and 0.01 diagnoses per patient in week 3 and beyond. Over time, the cost-effectiveness ratio increased from $98 per new diagnosis in week 1 to $576 per new diagnosis in week 2 and $5832 per new diagnosis in week 3. CONCLUSIONS: In patients referred for evaluation of palpitations, the diagnostic yield of continuous-loop event recording decreases rapidly after 2 weeks of monitoring. A 2-week monitoring period is reasonably cost-effective for most patients and should be the standard period for continuous-loop event recording for the evaluation of palpitations.
Entities:
Keywords:
NASA Discipline Cardiopulmonary; Non-NASA Center
Authors: Paddy M Barrett; Ravi Komatireddy; Sharon Haaser; Sarah Topol; Judith Sheard; Jackie Encinas; Angela J Fought; Eric J Topol Journal: Am J Med Date: 2013-10-15 Impact factor: 4.965
Authors: Jonathan S Steinberg; Niraj Varma; Iwona Cygankiewicz; Peter Aziz; Paweł Balsam; Adrian Baranchuk; Daniel J Cantillon; Polychronis Dilaveris; Sergio J Dubner; Nabil El-Sherif; Jaroslaw Krol; Malgorzata Kurpesa; Maria Teresa La Rovere; Suave S Lobodzinski; Emanuela T Locati; Suneet Mittal; Brian Olshansky; Ewa Piotrowicz; Leslie Saxon; Peter H Stone; Larisa Tereshchenko; Mintu P Turakhia; Gioia Turitto; Neil J Wimmer; Richard L Verrier; Wojciech Zareba; Ryszard Piotrowicz Journal: Ann Noninvasive Electrocardiol Date: 2017-05 Impact factor: 1.468
Authors: Jean-Claude Barthélémy; Séverine Féasson-Gérard; Pierre Garnier; Jean-Michel Gaspoz; Antoine Da Costa; Daniel Michel; Frédéric Roche Journal: Ann Noninvasive Electrocardiol Date: 2003-07 Impact factor: 1.468
Authors: Daniel Scherr; Darshan Dalal; Charles A Henrikson; David D Spragg; Ronald D Berger; Hugh Calkins; Alan Cheng Journal: J Interv Card Electrophysiol Date: 2008-04-03 Impact factor: 1.900