Literature DB >> 9629936

Simultaneous combined anterior and posterior lumbar fusion with femoral cortical allograft.

U Liljenqvist1, J P O'Brien, P Renton.   

Abstract

The radiographic fusion rates, graft behaviour and clinical outcome of 41 patient with simultaneous combined anterior lumbar interbody fusion and posterior arthrodesis with translaminar screws were reviewed independently. In all patients a femoral cortical allograft (FCA) ring filled with autologous iliac crest cancellous bone was used anteriorly to replace the disc and achieve interbody fusion. The follow-up averaged 30.6 months, with a minimum follow-up of 24 months. All patients had disabling low-back pain with different degrees of radiating leg pain and either discogenic pain (n = 24) or a postdiscectomy syndrome (n = 15) respectively postfusion syndrome (n = 2). The overall fusion rate was 95.2% (59 of 62 segments). Time to radiographic fusion averaged 8.7 months (range 2-34 months), and in 66.1% radiographic fusion occurred without significant subsidence. In 18.6% fusion with subsidence resulted from resorption of the FCA and in 15.3% the FCA had protruded into the vertebral body. The posterior intervertebral disc height (PIVDH) increased postoperatively by 2 mm on average. However, loss of PIVDH was the rule, and occurred within the first 12 postoperative months, resulting in a negligible final gain in height of 0.3 mm on average. The segmental lordosis was increased by 3 degrees; however, loss of lordosis during the first 6 postoperative months led to a final gain in lordosis of 1.3 degrees on average. Graft incorporation occurred in 16 of 62 segments (25.8%) and was observed at an average of 21.9 months postoperatively. Subjectively, 82.4% of the patients were satisfied or highly satisfied with the clinical result of the fusion operation. In conclusion, the described technique has proven to be highly effective in achieving a high fusion rate with a good patient outcome.

Entities:  

Mesh:

Year:  1998        PMID: 9629936      PMCID: PMC3611237          DOI: 10.1007/s005860050042

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  14 in total

1.  Anterior lumbar interbody fusion: does stable anterior fixation matter?

Authors:  S S Madan; J M Harley; N R Boeree
Journal:  Eur Spine J       Date:  2003-05-24       Impact factor: 3.134

2.  [Titanium vertebral body replacement of adjustable size. A prospective clinical trial].

Authors:  U Lange; S Edeling; C Knop; L Bastian; C Krettek; M Blauth
Journal:  Unfallchirurg       Date:  2006-09       Impact factor: 1.000

3.  Anterior interbody arthrodesis with percutaneous posterior pedicle fixation for degenerative conditions of the lumbar spine.

Authors:  D Greg Anderson; Amirali Sayadipour; Kevin Shelby; Todd J Albert; Alexander R Vaccaro; Michael S Weinstein
Journal:  Eur Spine J       Date:  2011-04-13       Impact factor: 3.134

4.  Evolution of Design of Interbody Cages for Anterior Lumbar Interbody Fusion.

Authors:  Kevin Phan; Ralph J Mobbs
Journal:  Orthop Surg       Date:  2016-08       Impact factor: 2.071

5.  Posterior lumbar interbody fusion using compressive bone graft with allograft and autograft in the pyogenic discitis.

Authors:  Ki Chan An; Joo Yong Kim; Tae Hyoung Kim; Jin Suck Kim; Dae Hyoun Park; Jeon Gyo Kim; Tae Woo Sung
Journal:  Asian Spine J       Date:  2012-03-09

6.  A prospective, randomised controlled trial of femoral ring allograft versus a titanium cage in circumferential lumbar spinal fusion with minimum 2-year clinical results.

Authors:  Patrick J McKenna; Brian J C Freeman; Robert C Mulholland; Michael P Grevitt; John K Webb; S H Mehdian
Journal:  Eur Spine J       Date:  2005-09-15       Impact factor: 3.134

7.  Anterior vertebral body replacement with a titanium implant of adjustable height: a prospective clinical study.

Authors:  Uta Lange; Sebastian Edeling; Christian Knop; Leonard Bastian; Michael Oeser; Christian Krettek; Michael Blauth
Journal:  Eur Spine J       Date:  2006-05-13       Impact factor: 3.134

8.  Radiological evaluation of anterior lumbar fusion using PEEK cages with adjacent vertebral autograft in spinal deformity long fusion surgeries.

Authors:  Jianqiang Ni; Yanping Zheng; Ning Liu; Xin Wang; Xiutong Fang; Rishabh Phukan; Kirkham B Wood
Journal:  Eur Spine J       Date:  2015-01-25       Impact factor: 3.134

9.  Risk factors for cage subsidence and clinical outcomes after transforaminal and posterior lumbar interbody fusion.

Authors:  Tiago Amorim-Barbosa; Catarina Pereira; Diogo Catelas; Cláudia Rodrigues; Paulo Costa; Ricardo Rodrigues-Pinto; Pedro Neves
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-08-31

10.  Comparison of instrumented anterior interbody fusion with instrumented circumferential lumbar fusion.

Authors:  S S Madan; N R Boeree
Journal:  Eur Spine J       Date:  2003-08-28       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.