Literature DB >> 9629489

Cyclosporine metabolite cross-reactivity in different cyclosporine assays.

J N Murthy1, R W Yatscoff, S J Soldin.   

Abstract

OBJECTIVES: There is a controversy regarding the role of cyclosporine (CsA) metabolites in both immunosuppression and toxicity, and measurement of the parent drug is commonly recommended. High performance liquid chromatography (HPLC) is the method commonly used for specific measurement of the parent drug, but is very time consuming. Antibody techniques are available but vary in specificity. Mixed lymphocyte culture assay (MLC) is a functional bioassay for the measurement of CsA which measures both parent drug and active metabolites. Because it is time consuming and labor intensive, it is not practical to use the MLC to monitor patient's CsA levels. The objective of this study is to evaluate the degree of cross-reactivity or interference among two different CsA immunoassays [(Immunoassay: CYCLO-Trac-RIA, Monoclonal-TDX; and two radioreceptor assays (RRA) (52 kDa immunophilin and cyclophilin)] with seven cyclosporine metabolites (AM19, AM1c9, AM4n9, AM1, AM9, AM1c, AM4n). The results are compared with a previously published MLC assay for the same metabolites.
METHODS: 500 ng/mL of each of the CsA metabolites was assayed in spiked blood samples with both RRA using 52 kDa immunophilin and commercial cyclophilin and two commonly used commercial immunoassay procedures. The results were compared to those obtained with the previously published MLC assay. RESULTS AND
CONCLUSION: The CYCLO-Trac-radioimmunoassay showed minimal cross-reactivity with all of the seven CsA metabolites tested and is more specific to parent CsA than the current Abbott monoclonal procedure for the measurement of CsA. However the cross-reactivity of the seven metabolites using the Abbott monoclonal assay matched closely with their pharmacological potency as measured in the MLC assay. The RRAs showed greater cross-reactivity for most of the CsA metabolites tested than that found in the immunoassay procedures.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9629489     DOI: 10.1016/s0009-9120(98)00007-1

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  9 in total

1.  Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry.

Authors:  Dongli Wang; Heather M Stapleton
Journal:  Anal Bioanal Chem       Date:  2010-05-01       Impact factor: 4.142

2.  Simultaneous quantification of T4, T3, rT3, 3,5-T2 and 3,3'-T2 in larval zebrafish (Danio rerio) as a model to study exposure to polychlorinated biphenyls.

Authors:  Xiaopeng Chen; Kyla M Walter; Galen W Miller; Pamela J Lein; Birgit Puschner
Journal:  Biomed Chromatogr       Date:  2018-01-29       Impact factor: 1.902

Review 3.  Thyroid hormone analogues and derivatives: Actions in fatty liver.

Authors:  Maria Coppola; Daniela Glinni; Maria Moreno; Federica Cioffi; Elena Silvestri; Fernando Goglia
Journal:  World J Hepatol       Date:  2014-03-27

4.  Detection and quantification of 3,5,3'-triiodothyronine and 3,3',5'-triiodothyronine by electrospray ionization tandem mass spectrometry.

Authors:  Yuntao Zhang; Abigail H Conrad; Gary W Conrad
Journal:  J Am Soc Mass Spectrom       Date:  2005-09-22       Impact factor: 3.109

Review 5.  Alternative matrices for therapeutic drug monitoring of immunosuppressive agents using LC-MS/MS.

Authors:  Mwlod Ghareeb; Fatemeh Akhlaghi
Journal:  Bioanalysis       Date:  2015       Impact factor: 2.681

6.  Isotope dilution tandem mass spectrometric method for T4/T3.

Authors:  Nadia Soukhova; Offie P Soldin; Steven J Soldin
Journal:  Clin Chim Acta       Date:  2004-05       Impact factor: 3.786

7.  Pediatric reference intervals for aldosterone, 17alpha-hydroxyprogesterone, dehydroepiandrosterone, testosterone and 25-hydroxy vitamin D3 using tandem mass spectrometry.

Authors:  Offie P Soldin; Hirsh Sharma; Lucas Husted; Steven J Soldin
Journal:  Clin Biochem       Date:  2009-02-06       Impact factor: 3.281

Review 8.  Steroid hormones: relevance and measurement in the clinical laboratory.

Authors:  Jennifer P Holst; Offie P Soldin; Tiedong Guo; Steven J Soldin
Journal:  Clin Lab Med       Date:  2004-03       Impact factor: 1.935

9.  Comparison of architect I 2000 for determination of cyclosporine with axsym.

Authors:  Nafija Serdarevic; Lejla Zunic
Journal:  Acta Inform Med       Date:  2012-12
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.