Radiation exposure to interventional radiologists during manual-injection digital subtraction angiography.

N Hayashi1, T Sakai, M Kitagawa, R Inagaki, T Yamamoto, T Fukushima, Y Ishii.   

Abstract

PURPOSE: We investigated the relationship between the amount of radiation exposure to the operator during table-side manual-injection angiographic procedures including digital subtraction angiography (DSA) and the operator's position, as well as a simple means to decrease radiation exposure.
METHODS: Measurement of radiation exposure was carried out with thermoluminescent dosimeters (TLDs) in nine abdominal angiographies. In the first study, radiation exposure during DSA or during fluoroscopy was measured using TLDs placed near the angiographic table. In the second study, radiation exposure to the interventional radiologist was measured during manual-injection DSA at a near and a far operator position.
RESULTS: Radiation exposure to the operator received during manual-injection DSA accounted for more than 90% of the total procedural exposure. The exposure to the operator markedly decreased at the far position compared with that at the near position when performing DSA.
CONCLUSION: Manual-injection DSA is the largest contributor to radiation exposure received by the interventional radiologist, therefore, the use of a power injector is always recommended when performing DSA. When manual-injection DSA is necessary, radiologists should position themselves as far away from the patient as possible.

Entities:  

Mesh:

Year:  1998        PMID: 9626442     DOI: 10.1007/s002709900252

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  3 in total

1.  Radiation exposure of operator performing interventional procedures using a flat panel angiography system: evaluation with photoluminescence glass dosimeters.

Authors:  Yoshinori Funama; Nozomu Nagasue; Kazuo Awai; Ichiro Sakamoto; Kiyotaka Kakei; Masamichi Shimamura; Yasuyuki Yamashita; Masataka Uetani
Journal:  Jpn J Radiol       Date:  2010-07-27       Impact factor: 2.374

2.  Radiation exposure to the primary operator during endovascular surgical neuroradiology procedures.

Authors:  K F Layton; D F Kallmes; H J Cloft; B A Schueler; G M Sturchio
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

Review 3.  Practice of ALARA in the pediatric interventional suite.

Authors:  Bairbre Connolly; John Racadio; Richard Towbin
Journal:  Pediatr Radiol       Date:  2006-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.