Literature DB >> 9622761

The effect of cross-sectional dimensional variations of square and rectangular chrome-cobalt archwires on torsion.

T R Meling1, J Odegaard.   

Abstract

The purpose of this investigation was to study the control of cross-sectional dimensions and edge bevel by various manufacturers in the production of chrome-cobalt archwires and this effect on transmitting torque through an .018 inc slot bracket system. Twenty-seven different square and rectangular chrome-cobalt wires commonly used in the edgewise technique supplied by five different manufacturers were studied with respect to dimensions, edge bevel, and mechanical properties in torsion. The mechanical study simulated application of torque to an individual tooth. Standard brackets with .018 inch slot heights were used. The results show that variation in cross-sectional dimension and edge bevel leads to variable torsional play (third-order clearance). As an example, .016 x .016 wires have a mean torsional play of as much as 26.8 degrees, with a range of 21.0 to 32.3 degrees. When using .016 x .016 wires, one must apply from 34.8 to 48.6 degrees of twist to get 20 N-mm of torsional moment. This variation is primarily due to the rather wide range in torsional play. As a result, the prediction by which a predetermined torsional moment can be delivered becomes uncertain. The results also show that because the working range in torsion of chrome-cobalt wires is somewhat limited due to high torsional stiffness, precise delivery of torsional moment based on the condition present in the oral cavity is difficult. The torsional stiffness varies between manufacturers within the various dimensional groups as a result of differences in cross-sectional geometry and material properties.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9622761     DOI: 10.1043/0003-3219(1998)068<0239:TEOCSD>2.3.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  9 in total

1.  Mechanical properties of beta-titanium wires.

Authors:  Júlio A Gurgel; Célia R M Pinzan-Vercelino; John M Powers
Journal:  Angle Orthod       Date:  2011-02-07       Impact factor: 2.079

2.  Super-elasticity in vitro assessment of CuNiTi wires according to their Austenite finish temperature and the imposed displacement.

Authors:  Noémie Copelovici; Maï-Linh Tran; François Lefebvre; Pascal Laheurte; Delphine Wagner
Journal:  Angle Orthod       Date:  2022-05-01       Impact factor: 2.684

3.  Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets.

Authors:  Thomas W Major; Jason P Carey; David S Nobes; Paul W Major
Journal:  J Dent Biomech       Date:  2010-06-27

4.  How orthodontic records can influence torque choice decisions?

Authors:  Dimitrios Mavreas; Enya Kuppens; Ronald Buyl; Bart Vande Vannet
Journal:  Eur J Orthod       Date:  2015-09-25       Impact factor: 3.075

5.  Torsional superelasticity of NiTi archwires.

Authors:  Yves Bolender; Anne Vernière; Christophe Rapin; Marie-Pierryle Filleul
Journal:  Angle Orthod       Date:  2010-11       Impact factor: 2.079

6.  Torque expression capacity of 0.018 and 0.022 bracket slots by changing archwire material and cross section.

Authors:  Angela Arreghini; Luca Lombardo; Francesco Mollica; Giuseppe Siciliani
Journal:  Prog Orthod       Date:  2014-09-25       Impact factor: 2.750

7.  Impact of different rectangular wires on torsional expression of different sizes of buccal tube.

Authors:  Shabnam Ajami; Afshar-Rasti Boroujeni
Journal:  J Clin Exp Dent       Date:  2018-01-01

8.  Effect of electrical spot welding on load deflection rate of orthodontic wires.

Authors:  Shiva Alavi; Arezoo Abrishami
Journal:  Dent Res J (Isfahan)       Date:  2015 Sep-Oct

9.  Dimensional variability of orthodontic slots and archwires: an analysis of torque expression and clinical implications.

Authors:  Michele Tepedino; Giordano Paiella; Maciej Iancu Potrubacz; Annalisa Monaco; Roberto Gatto; Claudio Chimenti
Journal:  Prog Orthod       Date:  2020-09-14       Impact factor: 2.750

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.