Literature DB >> 35099518

Super-elasticity in vitro assessment of CuNiTi wires according to their Austenite finish temperature and the imposed displacement.

Noémie Copelovici, Maï-Linh Tran, François Lefebvre, Pascal Laheurte, Delphine Wagner.   

Abstract

OBJECTIVES: To assess the super-elasticity of CuNiTi wires (Ormco, Glendora, Calif) according to their Austenite finish temperature (Af) and to the imposed displacement. The secondary objective was to compare the wire dimensions with the stated measurements and to study interbatch variability.
MATERIALS AND METHODS: 10 types of CuNiTi wires (Ormco, Glendora, Calif) (n = 350) were investigated at 36 ± 1°C, with conventional brackets (Victory Series, 3M Unitek, Monrovia, Calif). Tensile test with coronoapical displacement ranging from 1 to 5 mm of the canine bracket was imposed. The wire dimensions were initially measured from two batches (n = 10).
RESULTS: Dimensional heterogeneity varied by ± 2.00% compared to the manufacturer's data, and even up to 5.54% for 0.014-inch CuNiTi (P = .00069). However, all unloading forces were reproducible. In decreasing order, the forces delivered by a CuNiTi 27 were greater than those with CuNiTi 35 and 40. The super-elasticity was expressed only for displacements of 1 to 2 mm, at best up to 3 mm for 0.014-inch CuNiTi 27.
CONCLUSIONS: The value of Af as well as the amount of imposed displacement seem to influence the expression of the super-elasticity of CuNiTi wires and the amount of corrected malocclusion. Among the tested wires, under these experimental conditions, 0.014-inch wire could be suitable as a first archwire. CuNiTi 35, therefore, seems to offer the best compromise among the force level, the expression of super-elasticity and the amount of malocclusion correction.
© 2022 by The EH Angle Education and Research Foundation, Inc.

Entities:  

Keywords:  Malocclusion; Mechanical tests; Orthodontic wires; Orthodontics; Shape memory alloys

Mesh:

Substances:

Year:  2022        PMID: 35099518      PMCID: PMC9020406          DOI: 10.2319/027121-575.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.684


  33 in total

1.  Load-deflection characteristics of superelastic nickel-titanium orthodontic wires.

Authors:  Peter D Wilkinson; Peter S Dysart; James A A Hood; G Peter Herbison
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-05       Impact factor: 2.650

2.  Phase transformation analysis of varied nickel-titanium orthodontic wires.

Authors:  Chao-chao Ren; Yu-xing Bai; Hong-mei Wang; Yu-feng Zheng; Song Li
Journal:  Chin Med J (Engl)       Date:  2008-10-20       Impact factor: 2.628

3.  Torsional properties of Ni-Ti and copper Ni-Ti wires: the effect of temperature on physical properties.

Authors:  M P Filleul; L Jordan
Journal:  Eur J Orthod       Date:  1997-12       Impact factor: 3.075

4.  Comparative analysis of real and ideal wire-slot play in square and rectangular archwires.

Authors:  Luca Lombardo; Angela Arreghini; Elena Bratti; Francesco Mollica; Giorgio Spedicato; Mattia Merlin; Annalisa Fortini; Giuseppe Siciliani
Journal:  Angle Orthod       Date:  2014-11-18       Impact factor: 2.079

5.  Effect of archwire cross-section changes on force levels during complex tooth alignment with conventional and self-ligating brackets.

Authors:  Mona A Montasser; Ludger Keilig; Tarek El-Bialy; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  Am J Orthod Dentofacial Orthop       Date:  2015-04       Impact factor: 2.650

6.  The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics.

Authors:  F Miura; M Mogi; Y Ohura; H Hamanaka
Journal:  Am J Orthod Dentofacial Orthop       Date:  1986-07       Impact factor: 2.650

7.  Elastic flexural properties of multistranded stainless steel versus conventional nickel titanium archwires.

Authors:  Brian K Rucker; Robert P Kusy
Journal:  Angle Orthod       Date:  2002-08       Impact factor: 2.079

8.  Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurations.

Authors:  Riccardo Nucera; Elda Gatto; Chiara Borsellino; Pasquale Aceto; Francesca Fabiano; Giovanni Matarese; Letizia Perillo; Giancarlo Cordasco
Journal:  Angle Orthod       Date:  2013-09-25       Impact factor: 2.079

9.  Torque expression capacity of 0.018 and 0.022 bracket slots by changing archwire material and cross section.

Authors:  Angela Arreghini; Luca Lombardo; Francesco Mollica; Giuseppe Siciliani
Journal:  Prog Orthod       Date:  2014-09-25       Impact factor: 2.750

10.  Variability of slot size in orthodontic brackets.

Authors:  Clémentine Lefebvre; Hassan Saadaoui; Jean-Marc Olive; Stéphane Renaudin; Fabienne Jordana
Journal:  Clin Exp Dent Res       Date:  2019-07-11
View more
  1 in total

1.  The Effects of Temperature and Time of Heat Treatment on Thermo-Mechanical Properties of Custom-Made NiTi Orthodontic Closed Coil Springs.

Authors:  Thanate Assawakawintip; Peerapong Santiwong; Anak Khantachawana; Kawin Sipiyaruk; Rochaya Chintavalakorn
Journal:  Materials (Basel)       Date:  2022-04-26       Impact factor: 3.748

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.