Literature DB >> 9612812

Use of temporalis fascia for exposed hydroxyapatite orbital implants.

C R Pelletier1, D R Jordan, S M Gilberg.   

Abstract

The hydroxyapatite implant (Bio-Eye, Intergrated Orbital Implant, Inc., San Diego, CA, U.S.A.) has gained increasing popularity as an orbital implant in recent years. Several complications may occur, including infection, exposure, extrusion, and various peg problems. Exposure of the implant appears to be the most common complication, ranging up to 21.6%. Many techniques, including nonsurgical and surgical approaches, have been described to manage these exposures. When surgery is indicated, a patch graft may be required to cover the defect. We report our experience and technique with autogenous temporalis fascia as a patch graft. Autografts such as temporalis fascia are easily obtained, bring about no immunological reaction, and have no risk of infectious transmission.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9612812     DOI: 10.1097/00002341-199805000-00010

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  5 in total

1.  Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure.

Authors:  M S Sagoo; J M Olver
Journal:  Br J Ophthalmol       Date:  2004-07       Impact factor: 4.638

2.  Surgical coverage of exposed hydroxyapatite implant with retroauricular myoperiosteal graft.

Authors:  S L Liao; S C S Kao; J H S Tseng; L L-K Lin
Journal:  Br J Ophthalmol       Date:  2005-01       Impact factor: 4.638

3.  Treatment of intractable orbital implant exposure with a large conjunctival defect by secondary insertion of the implant after preceding dermis fat graft.

Authors:  Hyun Kyung Kim; Tae Yoon La
Journal:  Int J Ophthalmol       Date:  2013-04-18       Impact factor: 1.779

4.  Remove, rotate, and reimplant: a novel technique for the management of exposed porous anophthalmic implants in eviscerated patients.

Authors:  P Kaynak; G O Karabulut; C Ozturker; I Perente; B Gökyiǧit; A Demirok; O F Yilmaz
Journal:  Eye (Lond)       Date:  2014-02-07       Impact factor: 3.775

5.  The effect of orbital implantation on peripheral blood melatonin and sex hormone levels in child patients with congenital eyeball dysplasia.

Authors:  Junze Ma; Tao Liu; Jianqiang Qu
Journal:  Exp Ther Med       Date:  2017-07-07       Impact factor: 2.447

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.