Accuracy of the one-point in vivo calibration of "wired" glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration.

D W Schmidtke1, A Heller.   

Abstract

The hypothesis of the feasibility of one-point in vivo calibration of intravenously implanted glucose sensors during periods of rapid rise and decline of venous blood glucose concentration was tested. Miniature (5 x 10(-4) cm2 mass transporting area) glucose electrodes with 10-90% response times < 2 min, that did not consume oxygen, were implanted in jugular veins of systemically heparinized rats and used in 4-h experiments, during which the blood glucose concentration was amperometrically monitored. The glucose electrodes were made by electrically connecting ("wiring") reaction centers of glucose oxidase through an electron-conducting redox hydrogel to gold electrode surfaces. The redox polymer and enzyme constituting the electrode sensing layer were immobilized by cross-linking, and thus the electrodes had no diffusional and readily leached redox mediator. One hour after their implantation, the electrodes accurately tracked the blood glucose concentration when calibrated in vivo by a one-point calibration, when the glucose concentration was steady, when rising rapidly, and when declining steeply. For an assumed 2-min lag time, the sensor readings were well correlated with the true blood glucose concentrations, with linear regression analysis yielding a slope of 0.97 +/- 0.07 and an intercept (bias) of 0.3 +/- 0.3 mM. The correlation coefficient, r2, was 0.949 +/- 0.020, and the percent difference through the 2-22 mM range was 1.9 +/- 1.0%. The results suggest that, in combination with understanding and modeling of transient physiological differences between the subcutaneous and the blood glucose concentrations, it will be possible to calibrate by one-point in vivo calibration subcutaneously implanted sensors, even while the glucose concentration changes rapidly.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9608851     DOI: 10.1021/ac970932u

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  In vitro, in vivo and post explantation testing of glucose-detecting biosensors: current methods and recommendations.

Authors:  Heidi E Koschwanez; William M Reichert
Journal:  Biomaterials       Date:  2007-04-19       Impact factor: 12.479

2.  Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode.

Authors:  J G Wagner; D W Schmidtke; C P Quinn; T F Fleming; B Bernacky; A Heller
Journal:  Proc Natl Acad Sci U S A       Date:  1998-05-26       Impact factor: 11.205

Review 3.  Smartphone-Based Electrochemical Systems for Glucose Monitoring in Biofluids: A Review.

Authors:  Jie Xu; Zupeng Yan; Qingjun Liu
Journal:  Sensors (Basel)       Date:  2022-07-28       Impact factor: 3.847

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.