Determination of rotations in three dimensions using two-dimensional portal image registration.

A E Lujan1, J M Balter, R K Ten Haken.   

Abstract

The relative relationships among anatomic features visualized on planar radiographic images change due to rotations of the patient out of the imaging plane. These changes can be predicted a priori from a three-dimensional radiographic model of the patient. In this study we assess the feasibility of using that information together with a planar image feature alignment tool to account for out-of-plane rotations in the evaluation of subsequent clinical patient images. A series of digitally reconstructed radiographs (DRRs) with known patient rotations was generated from a computed tomography scan of an anthropomorphic head phantom. Fixed anatomic features were extracted, as seen in the DRRs of rotated anatomy and entered into a database. Alignment of features from test radiographs with those from an entry in this database yielded an estimate of rotation out of plane (database entry that resulted in the best fit via planar transformation) along with the planar components of setup errors in the rotated plane. Tests using DRRs and films show that it is possible to select anatomic features in AP skull radiographs with position and orientation sensitive to out-of-plane rotation.

Entities:  

Mesh:

Year:  1998        PMID: 9608481     DOI: 10.1118/1.598253

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Automated 2D-3D registration of a radiograph and a cone beam CT using line-segment enhancement.

Authors:  Reshma Munbodh; David A Jaffray; Douglas J Moseley; Zhe Chen; Jonathan P S Knisely; Pascal Cathier; James S Duncan
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  Automated 2D-3D registration of portal images and CT data using line-segment enhancement.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

3.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

4.  Detection of patient setup errors with a portal image - DRR registration software application.

Authors:  Kenneth Sutherland; Masayori Ishikawa; Gerard Bengua; Yoichi M Ito; Yoshiko Miyamoto; Hiroki Shirato
Journal:  J Appl Clin Med Phys       Date:  2011-02-18       Impact factor: 2.102

5.  ESTERR-PRO: a setup verification software system using electronic portal imaging.

Authors:  Pantelis A Asvestas; Konstantinos K Delibasis; Nikolaos A Mouravliansky; George K Matsopoulos
Journal:  Int J Biomed Imaging       Date:  2007

6.  Performance evaluation of an automated image registration algorithm using an integrated kilovoltage imaging and guidance system.

Authors:  Timothy Fox; Calvin Huntzinger; Peter Johnstone; Tomi Ogunleye; Eric Elder
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.