Pulsed Doppler ultrasonography guidance for catheterization of the subclavian vein: a randomized study.

J Y Lefrant1, P Cuvillon, J F Bénézet, M Dauzat, P Peray, G Saïssi, J E de La Coussaye, J J Eledjam.   

Abstract

BACKGROUND: Catheterization of the subclavian vein may lead to severe complications. The current randomized study compared a technique of pulsed Doppler ultrasonography guidance and the standard method for subclavian vein catheterization.
METHODS: Standard and Doppler ultrasonography guidance methods were performed by the same physician in 286 patients, 143 in each group. Primary end points were immediate complications (arterial puncture, pneumothorax, wrong position of catheter tip), failures, the number of subclavian vein catheterizations with immediate complication or failure, the number of skin punctures per catheterization, and the time to placement of the guide wire. The secondary end points were the determination of predicting factors of successful cannulation in each group.
RESULTS: Both groups were similar according to morphologic parameters of the patients. A greater number of subclavian vein catheterizations were performed on the right side using Doppler guidance (105 vs. 73, P < 0.01). Doppler guidance decreased complications (5.6% vs. 16.8%, P < 0.01), largely because of a smaller number of catheters for which the tip was defined to be in incorrect position (0.7% vs. 7.7%, P < 0.01). The time to catheterization was longer with Doppler guidance (300 vs. 27 s, P < 0.001). Failures, catheterizations of the subclavian vein with immediate complications or failure, and the total number of skin punctures per catheterization were similar in both groups. Using Doppler guidance, the presence of a good Doppler signal (124 of 143) was predictive of successful catheterization (123 successful cannulations, P < 0.001).
CONCLUSIONS: Doppler guidance reduces the incidence of inappropriately positioned subclavian catheters.

Entities:  

Mesh:

Year:  1998        PMID: 9605678     DOI: 10.1097/00000542-199805000-00009

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  14 in total

1.  Ultrasound guided central venous access.

Authors:  Manfred Muhm
Journal:  BMJ       Date:  2002-12-14

2.  [Ultrasound guidance for placement control of central venous catheterization. Survey of 802 anesthesia departments for 2007 in Germany].

Authors:  W Schummer; S G Sakka; E Hüttemann; K Reinhart; C Schummer
Journal:  Anaesthesist       Date:  2009-07       Impact factor: 1.041

Review 3.  A delayed diagnosis of a retained guidewire during central venous catheterisation: a case report and review of the literature.

Authors:  Yasemin Gunduz; Mehmet Bulent Vatan; Altug Osken; Mehmet Akif Cakar
Journal:  BMJ Case Rep       Date:  2012-11-19

4.  Verification of correct central venous catheter placement in the emergency department: comparison between ultrasonography and chest radiography.

Authors:  Maurizio Zanobetti; Alessandro Coppa; Federico Bulletti; Serena Piazza; Peyman Nazerian; Alberto Conti; Francesca Innocenti; Stefano Ponchietti; Sofia Bigiarini; Aurelia Guzzo; Claudio Poggioni; Beatrice Del Taglia; Yuri Mariannini; Riccardo Pini
Journal:  Intern Emerg Med       Date:  2012-12-16       Impact factor: 3.397

Review 5.  Totally implantable vascular access devices 30 years after the first procedure. What has changed and what is still unsolved?

Authors:  Roberto Biffi; Adriana Toro; Simonetta Pozzi; Isidoro Di Carlo
Journal:  Support Care Cancer       Date:  2014-06       Impact factor: 3.603

6.  Accuracy of Anatomical Landmarks in Locating the Internal Jugular Vein Cannulation Site among Different Levels of Anesthesia Trainees.

Authors:  Mohammad Helwani; Nahel Saied; Shigemasa Ikeda
Journal:  J Educ Perioper Med       Date:  2008-07-01

7.  Catheter-related Complications of Subcutaneous Implantable Venous Access Devices in Breast Cancer Patients.

Authors:  Ahmed El-Balat; Iryna Schmeil; Thomas Karn; Uwe Holtrich; Loreta Mavrova-Risteska; Achim Rody; Aly Youssef; Lars C Hanker
Journal:  In Vivo       Date:  2018 Sep-Oct       Impact factor: 2.155

8.  Doppler-guided cannulation of internal jugular vein, subclavian vein and innominate (brachiocephalic) vein--a case-control comparison in patients with reduced and normal intracranial compliance.

Authors:  Wolfram Schummer; Claudia Schummer; Wolf-Dirk Niesen; Hendrik Gerstenberg
Journal:  Intensive Care Med       Date:  2003-07-24       Impact factor: 17.440

Review 9.  Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization.

Authors:  Patrick Brass; Martin Hellmich; Laurentius Kolodziej; Guido Schick; Andrew F Smith
Journal:  Cochrane Database Syst Rev       Date:  2015-01-09

10.  Ultrasound and fluoroscopy-guided placement of central venous ports via internal jugular vein: retrospective analysis of 1254 port implantations at a single center.

Authors:  Se Jin Ahn; Hyo-Cheol Kim; Jin Wook Chung; Sang Bu An; Yong Hu Yin; Hwan Jun Jae; Jae Hyung Park
Journal:  Korean J Radiol       Date:  2012-04-17       Impact factor: 3.500