Determination of acidic herbicides using liquid chromatography with pneumatically assisted electrospray ionization mass spectrometric and tandem mass spectrometric detection.

B Køppen1, N H Spliid.   

Abstract

Liquid chromatography-pneumatically assisted electrospray mass spectrometry with negative ionization has been used for the determination of acidic herbicides in ground water. Eighteen pesticides or pesticide degradation products belonging to several different groups of acidic herbicides (phenoxy acids, sulfonylureas, phenols, etc.) were covered in the study. Optimization of electrospray inlet conditions is described as well as results from investigations of the linearity of the detector response. Conditions for tandem mass spectrometry (MS-MS) detection of characteristic daughter ions formed by collision-induced dissociation (CID) of the parent ion are described and a comparison of obtainable instrument detection limits by single MS and MS-MS was made. Detection limits using MS in the selected ion monitoring (SIM) mode were generally in the order of 1 microgram/l or below, whereas detection limits were three-four times higher using MS-MS detection. A principle of analysis is proposed based on single quadrupole MS as a method for quantitative determination followed by verification of positive findings by CID MS-MS. Application of the method for detecting acidic herbicides residues in a "real-world" ground water sample is demonstrated.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9604331     DOI: 10.1016/s0021-9673(97)01219-3

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Development of generic liquid chromatography-mass spectrometry methods using experimental design.

Authors:  Carmai Seto; Kevin P Bateman; Berton Gunter
Journal:  J Am Soc Mass Spectrom       Date:  2002-01       Impact factor: 3.109

2.  Mobility and persistence of the herbicide fomesafen in soils cultivated with bean plants using SLE/LTP and HPLC/DAD.

Authors:  Anna I G Costa; Maria Eliana L R Queiroz; Antônio A Neves; Roberta C de Assis; Carlos E S dos Soares; Antônio A da Silva; Leonardo D'Antonino; André F de Oliveira; Carlos R Bellato
Journal:  Environ Sci Pollut Res Int       Date:  2014-09-23       Impact factor: 4.223

3.  Liquid chromatography with post-column reagent addition of ammonia in methanol coupled to negative ion electrospray ionization tandem mass spectrometry for determination of phenoxyacid herbicides and their degradation products in surface water.

Authors:  Renata Raina; Michele L Etter
Journal:  Anal Chem Insights       Date:  2010-02-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.