Literature DB >> 9601972

MRI using hyperpolarized noble gases.

H Kauczor1, R Surkau, T Roberts.   

Abstract

The aim of this study was to review the physical basis of MRI using hyperpolarized noble gases as well as the present status of preclinical and clinical applications. Non-radioactive noble gases with a nuclear spin 1/2 (He-3, Xe-129) can be hyperpolarized by optical pumping. Polarization is transferred from circularly polarized laser light to the noble-gas atoms via alkali-metal vapors (spin exchange) or metastable atoms (metastability exchange). Hyperpolarization results in a non-equilibrium polarization five orders of magnitude higher than the Boltzmann equilibrium compensating for the several 1000 times lower density of noble gases as compared with liquid state hydrogen concentrations in tissue and allows for short imaging times. Hyperpolarization can be stored sufficiently long (3 h to 6 days) to allow for transport and application. Magnetic resonance systems require a broadband radio-frequency system - which is generally available for MR spectroscopy - and dedicated coils. The hyperpolarized gases are administered as inhalative "contrast agents" allowing for imaging of the airways and airspaces. Besides the known anesthetic effect of xenon, no adverse effects are observed in volunteers or patients. Pulse sequences are optimized to effectively use the non-renewable hyperpolarization before it decays or is destroyed, using fast low-flip-angles strategies to allow for dynamic/breath-hold imaging of highly diffusible (He) or soluble (Xe) gases with in vivo T1-times well below 1 min. Since helium is not absorbed in considerable amounts, its application is restricted to the lung. Xe-129 is also under investigation for imaging of white matter disease and functional studies of cerebral perfusion. Magnetic resonance imaging using hyperpolarized gases is emerging as a technical challenge and opportunity for the MR community. Preliminary experience suggests potential for functional imaging of pulmonary ventilation and cerebral perfusion.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9601972     DOI: 10.1007/s003300050479

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

Review 1.  Contrast-enhanced pulmonary MR imaging.

Authors:  O Haraldseth; T Amundsen; P A Rinck
Journal:  MAGMA       Date:  1999-08       Impact factor: 2.310

Review 2.  Lung imaging in asthmatic patients: the picture is clearer.

Authors:  Mario Castro; Sean B Fain; Eric A Hoffman; David S Gierada; Serpil C Erzurum; Sally Wenzel
Journal:  J Allergy Clin Immunol       Date:  2011-06-02       Impact factor: 10.793

3.  (3)He-MRI in follow-up of lung transplant recipients.

Authors:  Klaus Kurt Gast; Julia Zaporozhan; Sebastian Ley; Alexander Biedermann; Frank Knitz; Balthasar Eberle; Joerg Schmiedeskamp; Claus-Peter Heussel; Eckhard Mayer; Wolfgang Günter Schreiber; Manfred Thelen; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2003-10-16       Impact factor: 5.315

4.  Measuring surface-area-to-volume ratios in soft porous materials using laser-polarized xenon interphase exchange nuclear magnetic resonance.

Authors:  J P Butler; R W Mair; D Hoffmann; M I Hrovat; R A Rogers; G P Topulos; R L Walsworth; S Patz
Journal:  J Phys Condens Matter       Date:  2002-04-08       Impact factor: 2.333

Review 5.  13C imaging-a new diagnostic platform.

Authors:  Sven Månsson; Edvin Johansson; Peter Magnusson; Chun-Ming Chai; Georg Hansson; J Stefan Petersson; Freddy Ståhlberg; Klaes Golman
Journal:  Eur Radiol       Date:  2005-06-14       Impact factor: 5.315

6.  Lung injury induced by secondhand smoke exposure detected with hyperpolarized helium-3 diffusion MR.

Authors:  Chengbo Wang; John P Mugler; Eduard E de Lange; James T Patrie; Jaime F Mata; Talissa A Altes
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

7.  Free breathing 1H MRI of the human lung with an improved radial turbo spin-echo.

Authors:  Michael Völker; Philipp Ehses; Stefan Weick; Felix Arno Breuer; Martin Blaimer; Christian Hintze; Jürgen Biederer; Peter Michael Jakob
Journal:  MAGMA       Date:  2014-11-08       Impact factor: 2.310

8.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

Review 9.  Functional imaging of the lungs with gas agents.

Authors:  Stanley J Kruger; Scott K Nagle; Marcus J Couch; Yoshiharu Ohno; Mitchell Albert; Sean B Fain
Journal:  J Magn Reson Imaging       Date:  2015-07-27       Impact factor: 4.813

10.  Accessing long-lived nuclear singlet states between chemically equivalent spins without breaking symmetry.

Authors:  Yesu Feng; Ryan M Davis; Warren S Warren
Journal:  Nat Phys       Date:  2012-09-16       Impact factor: 20.034

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.